Coleman Mosquito Deleto 2200 Скачать руководство пользователя страница 2

This manual contains important information about the assembly, operation

and maintenance of this product and system. General safety information is
presented in these first few pages and is also located throughout the manu-
al. Particular attention should be paid to information accompanied by the
safety alert symbols: “      DANGER”, “

WARNING”, “      CAUTION”.

Keep this manual for future reference and to educate new users of this

product. This manual should be read in conjunction with the labeling on
the product.

Safety precautions are essential when any mechanical or propane fueled

equipment is involved. These precautions are necessary when using, stor-
ing, and servicing. Using this equipment with the respect and caution
demanded will reduce the possibilities of personal injury or property damage. 

The following symbols shown below are used extensively throughout this

manual. Always heed these precautions, as they are essential when using
any mechanical or fueled equipment. 

2

Contents

Introduction

2

General Safety Information

2 & 3

System Description

3

Assembly

4 - 7

Leak Check

6

Operation

7

Moving Unit

8

Placement

8 & 9

Helpful Hints

9

Storage

9

Maintenance

9

Troubleshooting

10

Service

10

Mosquito Deleto

TM

Refills

10

Replacement Parts

11

Guarantees

12

Warranty

12

General Safety Information 

cont.

DANGER

DANGER indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

WARNING

WARNING

WARNING indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate personal injury, or property
damage.

Failure to comply with the precautions and instructions provided with
this mosquito trap can result in death, serious bodily injury and property
loss or damage from hazards of fire, explosion, burn, asphyxiation, and/or
carbon monoxide poisoning. 

Only persons who can understand and follow the instructions should use
or service this mosquito trap. 

If you need assistance or information such as an instruction manual or
labels, contact The Coleman Co., Inc.

DANGER

General Safety Information

Improper installation, adjustment, alteration,
service or maintenance can cause injury or prop-
erty damage. Read the instructions thoroughly
before installing or servicing this equipment.

WARNING

WARNING: For Outdoor Use Only

• This product is fueled by propane gas. Propane gas is invisible, 

odorless, and flammable. An odorant is normally added to help 
detect leaks and can be described as a “rotten egg” smell.  The 
odorant can fade over time so leaking gas is not always detectable
by smell alone.

• Propane gas is heavier than air and leaking propane will sink to 

the lowest level possible. It can be ignited by ignition sources 
including matches, lighters, sparks or open flames of any kind 
many feet away from the original leak. Use only propane gas set 
up for vapor withdrawal.

• Propane gas should be stored or used in compliance with local 

ordinances and codes or with ANSI/NFPA 58. Turn off propane 
when not in use.

• The propane tank must always be stored outdoors in a well-ventilat-

ed space. Never store propane tank in an enclosed area (house, 
garage, etc.). If unit is to be stored indoors, disconnect the propane
tank for outdoor storage.

WARNING

Combustion by-products produced when using this product contain
chemicals known to the State of California to cause cancer, birth defects,
or other reproductive harm.

Mosquito Deleto

TM

System

No zapping

No lotions

No sprays

No electrical cords

Mosquitoes have highly developed senses for detecting humans 

and animals.

Mosquitoes are attracted to three things:

• carbon dioxide from breath
• body heat
• faint odors emitted by animals and humans.

The Mosquito Deleto

TM

Trap lures mosquitoes to it by emitting 

heat, carbon dioxide and a special mosquito attractant called 
Octenol. The Mosquito Deleto

TM

Inhibitor emits and circulates a 

patented scent that inhibits mosquitoes’ ability to detect humans.

The irresistible combination attracts mosquitoes to the trap where 
they are captured. . .never to bother you again!

This instruction manual will assist you in setting up your new 
Mosquito Deleto

TM

System. Please refer to the instructions includ-

ed with the Inhibitor for details on use, storage, specifications.

Introduction

Содержание Mosquito Deleto 2200

Страница 1: ...436 6 055 766 D466578 D468389 U S and other Patents Pending 2002 The Coleman Company Inc www coleman com IMPORTANT Read this manual carefully before assembling using or servicing this unit Keep this manual for future reference If you have questions about assembly operation servicing or repair please call Coleman at 1 800 835 3278 or TDD 316 832 8707 For Outdoor use only ...

Страница 2: ... information such as an instruction manual or labels contact The Coleman Co Inc DANGER General Safety Information Improper installation adjustment alteration service or maintenance can cause injury or prop erty damage Read the instructions thoroughly before installing or servicing this equipment WARNING WARNING For Outdoor Use Only This product is fueled by propane gas Propane gas is invisible odo...

Страница 3: ...nt during operation of this product get fresh air immediately For outdoor use only Never use inside house or other unventilated or enclosed areas This unit consumes air oxygen Do not use in unventi lated or enclosed areas to avoid endangering your life DANGER Front Bar Base Collar Consumables Bag Feet Axle Tank Retainer Hardware Tank Cover Wheels Head Assembly Mosquito DeletoTM Inhibitor Axle Bush...

Страница 4: ...sting of contents for the model you purchased Step 2 With a lightweight hammer tap Axle Bushings into Base Make sure Bushings are fully seated TOOLS REQUIRED OTHER ITEMS not provided Standard Phillips head screwdriver 7 16 end wrench Lightweight hammer Mosquito DeletoTM Inhibitor Refill Linalool Stakes Adhesive Trap Mosquito DeletoTM Octenol Lure Refill Axle Bushing Base Axle Bushings will receive...

Страница 5: ...t Head Assembly on legs with Handle positioned as shown Step 7 cont Step 6 Turn Head Assembly over while holding Lid closed Attach Collar to Head Assembly Align ribs on Collar with Ignitor Install screws and tighten Ignitor Ribs on Collar Install Tank Retainer at Leg position opposite the Handle Grip Tank Retainer Handle Grip Actual size Actual size Actual size Step 7 Install Carriage Bolts Washer...

Страница 6: ...ylinder Valve OFF Disconnect reconnect and perform another leak check If you continue to see bubbles after several attempts cylinder valve or hose is defective and should be replaced Defective cylinders should be returned to cylinder s place of purchase If NO bubbles appear at connec tion the connection is secure Turn Cylinder Valve OFF Cylinder Valve NOTE Whenever gas connection is loosened or re...

Страница 7: ...stall or remove propane tank while unit is operating near flame pilot lights other ignition sources or while unit is hot to touch This unit is hot during use and can ignite flammables Keep gasoline and other flammable liquids and vapors well away from unit The propane tank must always be stored outdoors in a well ventilated space Never store propane tank in an enclosed area house garage etc If uni...

Страница 8: ...o operate around the clock in your yard The Trap continuously attracts traps and kills mos quitoes all day and all night 6 Together the Mosquito DeletoTM Inhibitor and Trap are a strong defense against mosquitoes 7 Place the inhibitor unit per instructions in the inhibitor package To Turn On cont To Turn Off Verify ignition by observing gauge Turn cylinder valve OFF Unit can be moved from location...

Страница 9: ...ved before doing maintenance WARNING 1 Use the Mosquito DeletoTM Inhibitor to push mosquitoes away from you use the Mosquito DeletoTM Trap to attract and kill mosquitoes 2 The Mosquito DeletoTM Inhibitor is designed for occasional use Turn it on when going outdoors to gently disperse the scent that blocks the mosquitoes sensors Turning the unit off will close the vents and preserve the unit for fu...

Страница 10: ...pply hose is bent or kinked Straighten hose Adhesive Panels Panels exposed to direct sunlight Move out of direct sunlight If desired replace dripping 10 Mosquito DeletoTM Refills Mosquito DeletoTM Inhibitor Model 2950 603 Mosquito DeletoTM System Refill Model 2950 700 Mosquito DeletoTM Octenol Lure Refill Model 2960 601 Mosquito DeletoTM Trap Cartridge Refill Model 2960 602 Mosquito DeletoTM Inhib...

Страница 11: ...ssembly no wires 5 2910A0981 Thermometer 6 2910 3581 Transition Piece w 3 bolts 7 2910 0801 1 Individual Leg 8 2910 3601 Axle 2 Wheels 9 2910 3591 Base Assembly D ring 2 Feet Support Bar Hardware 10 2910 0931 Tank Holder Assembly 11 2950 3701 Tank Cover 12 2910 8001 Head Assembly 13 2910 0311 Ignitor Button 14 2910 0371 Gas Tip 1 2 9 6 8 4 7 11 3 5 10 12 14 13 ...

Страница 12: ...structions or failure to follow maintenance instructions commercial in profit or non profit instructional or rental applications disassembly repair or alteration by anyone other than Coleman or an authorized service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes Coleman shall not be liable for any incidental or consequential damages caused by the...

Отзывы: