![Coleman Exponent Apollo 9760 Series Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/coleman/exponent-apollo-9760-series/exponent-apollo-9760-series_instructions-for-use-manual_2636497010.webp)
FIG. 22
To Light
9
■
Make sure fuel bottle is lying level on its side with the
FUEL VALVE
up (Fig. 20).
■
Turn flame adjuster back and forth several times to clean generator tip (Fig. 21).
■
Turn flame adjuster to “High/Light” (Fig. 22).
■
Hold lighted match at burner and then open fuel valve (Fig. 20 and 23).
■
CAUTION:
If stove burns with a high yellow flame or if liquid fuel appears in the
burner, immediately turn
FUEL VALVE
“OFF.” Allow stove to cool. Carefully
review the troubleshooting section before relighting stove.
■
After stove warms up (approx. 1 minute), pump an additional 40 strokes. Flame
may be adjusted to desired heat with
FLAME ADJUSTER
. Periodically turn
flame adjuster back and forth several times to clean generator tip (Fig. 21).
■
Pump as required to maintain flame height.
NEVER FILL OR LIGHT STOVE INSIDE HOUSE, CAMPER, OR TENT.
WARNING: Keep fuel bottle at least 8” from lit stove.
FIG. 20
FIG. 21
FIG. 23
English-9
To Turn Off
10
FUEL VALVE
FIG. 24
■
Turn
FUEL VALVE
fully “OFF” (Fig. 24).
■
Be sure flame is extinguished. Flame will linger on
burner for 1-2 minutes after fuel valve is “OFF”.
WARNING
• Always turn fuel valve off before
removing hose. Never remove
hose from bottle near ignition
sources, while stove is lit, or hot
to touch.