background image

                                                                                                       - 13 -

                                   

For more information, visit www.desatech.com

 

• 

Install the identification label enclosed with the 
gas valve regulator to the valve body where it can 
easily be seen (see figure 23). 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 

 
 
 
 
 
 
 
 

FACE EXTENSION (FOR MODEL CD32M ONLY) 
 

Model CD32M comes equipped with a front face extension.  
The front face extension would add 3- ½” to the width and ¾” 
to the height of the fireplace face. 
 
To install the face extension: 
 

• 

Remove the existing screws from front face assembly 
as shown in figure 24. 

 

• 

Align holes on top face extension (figure A) with 
holes on the top side of the front face assembly and 
secure with screws previously removed (follow this 
step to install left and right face extension). 

 

• 

Secure top face extension with left and right face 
extensions with two sheet metal screws (figure B). 

 

 
 

 
 

WARNING: The conversion kit must be installed by a

qualified service technician in accordance with the
manufacturers instructions and all applicable codes and
requirements of the authority having jurisdiction.  If any
information in these instructions is not followed correctly,
a fire, explosion or production of carbon monoxide may
result causing property damage, personal injury or loss of
life.  The qualified service technician is responsible for the
proper installation of this conversion kit.   

FIGURE A

FIGURE B

Figure 24      FRONT FACE EXTENSION 

 

Figure 23     GAS CONTROL VALVE CONVERSION

WARNING: Never use an open flame to check

for a leak. Apply commercial leak test solution to all
gas joints. Bubbles forming show a leak. Correct all
leaks at once. 

WARNING: Test all gas piping and connections

for leaks after installing or servicing. Correct leaks at
once. 

Содержание CD32M

Страница 1: ...EM installation in a manufactured mobile home and must be installed in accordance with the manufacturers instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or the Mobile Home Standard CAN CSA Z240 MH Series in Canada This fireplace is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with ...

Страница 2: ...ING PG 6 7 GAS SUPPLY TESTING AND HOOK UP PG 7 8 PILOT ADJUSTMENT PG 8 9 SPECIFICATION TABLE PG 8 10 GLASS PANEL REMOVAL PG 9 11 LOG INSTALLATION PG 9 12 BURNER FLAME ADJUSTMENT PG 10 13 WIRING DIAGRAM PG 10 14 LIGHTING INSTRUCTIONS PG 11 15 CONVERSION KIT PG 12 13 16 TROUBLESHOOTING PG 14 17 ILLUSTRATED PARTS BREAKDOWN PG 15 16 18 ILLUSTRATED PARTS LIST PG 17 19 ACCESSORY AND REPLACEMENT PARTS PG...

Страница 3: ...or Canada The installation must conform to local codes or in the absence of local codes with the national Fuel Gas Code ANSI Z223 1 current installation code CAN CGA B149 This appliance complies with ANS Z21 88 2000 CSA 2 22 2000 VENTED GAS FIREPLACE HEATERS SELECTING LOCATION To determine the safest and most efficient location for the fireplace you must take into consideration the following guide...

Страница 4: ...and to replace any part of the control ignition system and other related components that has been submerged under water MINIMUM CLEARANCES TO COMBUSTIBLES Back and side of fireplace 0 Floor 0 Perpendicular wall 6 Front 36 Top of Standoffs 0 MANTEL CLEARANCES Woodwork such as wood trims mantels and other combustible materials should be placed within the required clearance specified on figure 2 VENT...

Страница 5: ...orner H not to be installed above a meter regulator within 3 feet 914mm horizontally from the centerline of the regulator I 36 914mm clearance in U S and 72 1829mm in Canada to service regulator vent outlet J 12 305mm clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K 36 914mm clearance to a mechanical air supply inlet L 84 2134mm clearanc...

Страница 6: ...ion must be removable for service pipe inspection The vent system serves as the chimney as well as the combustion air supply air intake The horizontal run must have a rise of 6 mm for every 1 foot 305 mm of horizontal run towards the termination Never allow the vent to run downward The maximum horizontal run depends on the vertical rise from fireplace adapter collar to the vent termination see tab...

Страница 7: ...eplace ELECTRICAL HOOK UP AND REMOTE RECEIVER DIAGRAM A wire way with two receptacles has been supplied for your convenience and is located on the lower right hand side of the appliance see figure 10 ROOF PITCH ft mm FLAT 7 12 1 305 7 12 8 12 1 5 457 8 12 9 12 2 610 9 12 10 12 2 5 762 10 12 11 12 4 1219 12 12 14 12 5 1524 14 12 16 12 6 1829 16 12 18 12 7 2134 18 12 20 12 7 5 2286 20 12 21 12 8 243...

Страница 8: ...ings are provided on the gas control valve for pressure test gauge connections see figure 12 GAS LINE HOOK UP Gas line hook up should be done by your gas supplier or licensed service technician NOTE Before you proceed make sure your gas supply is off A manual shut off valve has been included in the fireplace s gas supply system However consider installing an extra shut off valve outside the applia...

Страница 9: ...ipping and handling If this is the case some minor readjustments may be necessary and should be done by a qualified service technician The proper settings for the thermopile height should be at a distance of 3 8 10mm to 13mm from the pilot flame as shown in figure 16 SPECIFICATIONS CAUTION All gas piping and connections must be tested for leaks after the installation is completed After ensuring th...

Страница 10: ...lace FOR MODELS CD32M AND CD36M SERIES Place log 1 back log on top of grate Make sure the notches in the bottom of the log fit over the grate Rest log 2 large front log on the pins on the front part of the grate Place log 3 C shaped crossover log onto the rear and front logs Make sure it is seated properly on the smooth surface on the front log and on the pin on the back log as shown below Place l...

Страница 11: ...r to section on clearances on page 3 Louvered openings must not be obstructed and upper and lower panels must remain accessible for service Use only heat resistant non combustible mortar or adhesive when securing decorative facing materials OPERATING GUIDELINES When lit for the first time the fireplace may emit a slight odor for about 16 to 24 hours This is normal and is due to the curing of the l...

Страница 12: ... 11 For more information visit www desatech com ...

Страница 13: ...g up until it disengages from the barrel Do not remove the retainer clip see figure 21 Remove the pilot orifice from inside the barrel using a 5 32 allen wrench to unscrew the orifice Replace pilot orifice with LP orifice supplied with this kit The number 30 is stamped on the sleeve for identification Insert the small end of the new pilot orifice into the barrel and thread until tight with the all...

Страница 14: ...right face extensions with two sheet metal screws figure B WARNING The conversion kit must be installed by a qualified service technician in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction If any information in these instructions is not followed correctly a fire explosion or production of carbon monoxide may result causi...

Страница 15: ...ction between the valve and thermocouple are tight and secured Check remote wires for proper connections Jumper wire across terminals at remote control if burner comes on replace defective remote If okay jumper wire across remote control at valve if burner comes on wires are faulty or connections are bad Check thermopile with millivolt meter Take reading at thermopile terminals of gas valve Should...

Страница 16: ... 15 For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MODELS CD32M AND CD36M SERIES ...

Страница 17: ... 16 For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MODEL CD42M ...

Страница 18: ...24460 CONDUIT ASSEMBLY GAS 1 21 109082 03 109082 01 109082 02 HEAT SHIELD 1 22 27253 27253 27253 LABEL NOTICE 1 23 109222 01 109006 01 108778 01 LOG SET 1 24 11102 11102 11102 SCREW 8 32 x 3 8 PPH ZINC 2 25 11105 11105 11105 SCREW 10 x 1 2 ZINC 9 26 11179 11179 11179 SCREW 10 24 x 1 4 ZINC 4 27 11237 11237 11237 SCREW TRILAB M4 x 8MM 1 28 14389 14389 14389 VALVE HI LO SIT NAT 1 29 14492 14492 1449...

Страница 19: ... 18 For more information visit www desatech com ACCESSORY AND REPLACEMENT PARTS ...

Отзывы: