Operation
1) Open/unscrew the Air Purge Valve on the the Filter Pump; air is released as water fills the
Filter Pump.
2) When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe
away any water.
3) Test the GFCI plug.
4) Start the Filter Pump by turning on the switch to the “I” position.
GFCI Test
RESET
TEST
RESET
TEST
RESET
TEST
A
B
C
D
5
PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain
pedestal made of wood or concrete before use.
There should be two holes 7mm in diameter on the pedestal, the
space between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All the
pedestal parts should weigh over 18kgs at least to prevent the pump
from accidental falling.
6
6
256
270
300
450
Fig.1
NOTE
:
You must clean the filter cartridge every day and open the top valve let the air out
then close it before using the pump, otherwise the pump may not work.
A. To test the GFCI plug, insert it into a grounding type receptacle.
B. Press the “RESET” button; the indicator turns red.
NOTE:
If the indicator light is not on, the test has failed.
C. Press the “TEST” button. The indicator turns off.
NOTE:
If the indicator light is not off, the test has failed.
D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use.
WARNING:
RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH
USE.
WARNING:
DO NOT USE THE PUMP IF THE ABOVE TEST FAILS. Please contact your local
Coleman Customer Service.