5. CEILING PLENUM INSTALLATION REQUIREMENT
1. The ceiling plenum must be installed under the roof
opening.
The ceiling plenum bolts below the roof top unit.
Compression of the framed ceiling cavity between the
roof top unit and the ceiling plenum is what holds both
components in place.
2. Ceiling cavity depth (the measurement from the ceiling to
the roof – maximum 6”).
3. The 115 VAC service for the roof top unit must be routed
into the ceiling plenum. To prevent wire pinching and to
promote ease of installation, allowances must be made for
routing the 115 VAC supply wiring into the front of the
roof opening.
4. The wirebox has a 9 pin receptacle extending from the
front. This mates with the roof unit 115 volt electrical
conduit. When making this connection, verify that the
plugs are properly aligned and have snapped together
securely.
5. The wirebox for the heat/cool units will have a two pin
receptacle which mates with the umbilical plug from the
heater assembly.
6. LOW VOLTAGE CONTROL WIRING (WALL
THERMOSTAT)
A.
A low voltage terminal strip on the front of the box
connects to the low voltage control wires. The wires
attach by 1/4" quick connects.
B.
The low voltage control wiring must be run from the
wall thermostat mounting location to the wirebox low
voltage terminals. To prevent wire pinching and to
promote ease of installation, allowances must be
made for routing the low voltage wiring into the front
of the opening.
Standard Control Box
Zone Control Box
Plenum Terminal
Designation
Thermostat Wire
Connection
Function of Low Voltage Terminal Extending From Ceiling
Plenum
R+
Red
Pr12 VDC to upper unit control box
Cool Shed
(2 Terminals)
White
Jumper Wire
Removing jumper wire will allow system to be connected to N.C.
contacts of a load shed system
Heat Shed
(2 Terminals)
White
Jumper Wire
Removing jumper wire will allow system to be connected to N.C.
contacts of a load shed system
Room (2 Terminals)
Any
The remote room temperature sensor attaches here*
Freeze (2 Terminals)
White
Freeze sensor attaches here
Gen
Any
Allows system to connect to an automatic start generator system
B-
Blue
Provides -12 VDC to upper unit control box
Sig 1
Purple
Communication line between upper unit control box and thermostat
Sig 2
Black
Communication line between upper unit control box and thermostat
* Zone 1 has option of using thermostat as room sensor
Cool Only
Boxes
Plenum Terminal
Designation
Thermostat Wire
Connection
Function of Low Voltage Terminal
Extending From Ceiling Plenum
Heat Ready
Boxes
Yes
B
BLUE
Completes -12 VDC circuit for all relays
Yes
Yes
Y
YELLOW
Energizes coil on Compressor Relay
Yes
Yes
GH
GREEN
Energizes coil on High Fan Relay
Yes
Yes
GL
GRAY
Energizes coil on Low Fan Relay
Yes
Yes
FREEZE
WHITE
Evaporator Freeze Sensor Connections
Yes
Yes
FREEZE
No
W
WHITE
Energizes coil on Heat Relay
Yes