background image

4

3

Features

Warning

Lid Opening/Closing mechanism

Operating Panel

Handle

Lid

Press down

Lid Latch

Air outlet vent

Air intake area

Filter

DC power socket

FREEZE-2

Temperature setting indicators flash.

Power button

Power indicator

Low-battery light

Warning light

COOL-1

Cools the Power Cooler to 
approximately 50

˚

F (10

˚

C)

COOL-2

Cools the Power Cooler to 
approximately 43

˚

F (6

˚

C)

FREEZE-1

Cools the Power Cooler to 
approximately 19

˚

F (-7

˚

C)

Cools the Power Cooler to 
approximately -0.4

˚

F (-18

˚

C)

Cools the Power Cooler to approximately 37

˚

F (3

˚

C)

COOL-3

Power Cable and Power Supply

Opening/Closing the lid

Lid open

Opening the lid

Closing the lid

Power
plug

Household

Power Supply

DC plug

DC

Power Cable

The lid is equipped with a mechanism that prevents the lid 
from closing quickly. If the lid is half open, the mechanism 
will not operate properly, and the lid may shut forcefully un-
der its own weight. Therefore, open the lid completely to ac-
tivate the mechanism.

Pull up

To avoid malfunction, the switches will only operate after being pressed for approximately one second. Continue to 
press until a high-pitched tone is emitted. 

Press and hold the power button 
to turn the power on or off.

When the temperature in the cooler reaches 
the set temperature, the flashing lights change 
to continuous illumination.

(5232F640T)

(5726-3661)

Do not operate the product in extremely hot or cold environment (see page 10 for 
recommended operating temperature range). If the cooler internal air temperature 
drops below -40˚F(-40˚C) or rises above 140˚F(60˚C), the "on/off" light, "Freeze-1" light, and "Freeze-2" light will all 
flash, warning users to immediately turn off the product and correct the extreme temperature condition. The cooler can 
be turned back on once the ambient temperature condition is within the recommended range and the cooler internal air 
temperature rises above -40˚F(-40˚C) or drops below 140˚F (60˚C). 

The low-battery light flashes when the input voltage is low. Use the light to 
check the battery condition.

The warning light illuminates when the temperature of the unit’s 
cooling system rises. 

If the warning light illuminates, remove any objects blocking the air intake area 
or air outlet vent. Make sure that the filter is clean. If it is dirty, perform mainte-
nance (see page 8). Make sure the unit is located in an environment below 
120˚F. When the environment returns to normal, the warning light will shut off.

Содержание 5726-750

Страница 1: ...ions disassembly repair or alteration by anyone other than Coleman or an authorized service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes COLEMAN SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY THE BREACH OF ANY EXPRESS OR IMPLIED WARRANTY OR CONDITIONS EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRA...

Страница 2: ...use damage to cooler Do not let children use the product alone Keep infants away Warning Prohibited May cause electric shock short circuit or combustion Do not use if either the household power supply cable or vehicle power cable is damaged or if the DC power socket is loose Prohibited The temperature of cooler contents may rise causing damage or spoilage Avoid using in places expected to reach 12...

Страница 3: ...gh pitched tone is emitted Press and hold the power button to turn the power on or off When the temperature in the cooler reaches the set temperature the flashing lights change to continuous illumination 5232F640T 5726 3661 Do not operate the product in extremely hot or cold environment see page 10 for recommended operating temperature range If the cooler internal air temperature drops below 40 F ...

Страница 4: ...tting will return to COOL 1 when switched on again Always verify the temperature setting when turning on Condensation may form on the outside of the unit depending on the environment it is being used in This may cause corrosion so wipe away condensation as quickly as possible Condensation is a natural phenomenon and is not a sign of malfunction Protrusion DC socket Indentation DC power cable On Fl...

Страница 5: ...nsation put water sensitive items in a plastic bag or container before storing If the air intake filter is dirty product performance will be hampered Clean the air intake area with a vacuum cleaner at least once a month Remove stubborn dirt by rubbing gent ly with a commercially available brush Inside the cooler Lay bottles on their side to prevent them from falling and breaking When there are few...

Страница 6: ...e are ashes or dust in the power supply socket Clean the power supply socket Electrical connections are not properly connected Check electrical connections The lid is not completely closed Close the lid properly and lock it The air vents are covered Check both the air intake and the air outlet vents Removeanyitemscoveringthevents The lid is being opened and closed too often Minimize opening and cl...

Отзывы: