Coleman 36MWL Скачать руководство пользователя страница 5

                                                                                                      4                                               

For more information, visit www.desatech.com 

 

OUTSIDE AIR KIT (MODEL AK-6) 

The installation of an outside air kit should be installed during 
the rough framing of the fireplace due to the nature of its 
location.  Outside combustion air is accessed through the 
mobile home floor (Refer to AK-6 Installation Instructions for 
details).  In some instances, a wall installation is required (see 
figure 5). 
 

 
 
Note: An AK-6WAI Air Kit must be ordered when a sidewall 
installation is required (see accessories on page 11). 

FAN KIT ASSEMBLY: VCBK3E 

A fan kit assembly is preinstalled in this fireplace. Use of 
blowers or fans other than manufactured by DESA voids the 
warranty. Fan is operated by simply pressing the rocker switch 
in the lower right corner of the fireplace face (see figure 6). 

NOTE:

  Fireplace must be wired to the house electrical 

system in order for fan to operate.  This fan system does not 
require a wall switch.   
Electrical connections are made through the cover on the side 
of the fireplace illustrated in Figure 7.  Use 14 AWG copper 
wire for all connections.  Be certain the fireplace is properly 
grounded. 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CHIMNEY PIPE 

The DESA chimney system consists of 12, 18, 24, 36 and 48 
inch, snap-lock double-wall pipe segments, planned for 
maximum adaptability to individual site requirements.  Actual 
lengths gained after fitting overlaps must be taken into 
consideration (lineal gain) and are given in the following 
chart: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
There are three vent kits available, which have been specially 
designed for common installations in manufactured (mobile) 
homes: CPMH-A/AC (8’ Vent Kit), CPMH-A/ACA (9’ Vent 
Kit) and CPMH-A/ACB (9’ Vent Kit).  The contents of these 
kits are listed under accessories on page 11.  Most chimney 
systems for manufactured houses require a standard straight 
installation as described in this section.  If an uncommon 
offset installation is required, see page 10.   
Important: If the height of the chimney assembly exceeds 
requirements for transportation of the home, the chimney 
installation may be completed after the home is sited. 
Note: the termination must always be installed after the home 
is sited. 

ASSEMBLING AND INSTALLING THE DOUBLE 
WALL CHIMNEY SYSTEM 

Each double wall chimney section consists of a galvanized 
outer pipe, a stainless steel inner flue pipe and a wire spacer.  
The pipe sections must be assembled independently as the 
chimney is installed.  When starting chimney directly to the 
fireplace, the inner flue pipe section must be installed first 
with the lanced side up.  The outer pipe section can then be 
installed over the flue pipe section with the hemmed end up. 
Press down on each pipe section until the lances securely 
engage the hem on the fireplace starter.  The wire will assure 
the proper spacing between the inner and outer pipe sections. 

WARNING:

  THE OPENING IN THE COLLAR AROUND 

THE CHIMNEY AT THE TOP OF THE FIREPLACE MUST 
NOT BE OBSTRUCTED. NEVER USE BLOWN 
INSULATION TO FILL THE CHIMNEY ENCLOSURE. 
Continue to assemble chimney sections as outlined above, 
making sure that both the inner and outer pipe sections are 
locked together.

   

When installing double wall “snap lock” 

chimney together, it is important to assure the joint between 
the chimney sections is locked. Check by pulling chimney 
upward after locking. The chimney will not come apart if 
properly locked.  It is not necessary to add screws to keep the 
chimney together (Exception – see page 9 figure 23). 

 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5 

 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6 

OFF

ON

 

Figure 7 

 

 

Figure 8 

Содержание 36MWL

Страница 1: ...le not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes A DESA hood must be installed when using a vent free gas log heater...

Страница 2: ...HEARTH EXTENSION PG 3 6 OUTSIDE AIR KIT INSTALLATION PG 4 7 FAN KIT ASSEMBLY PG 4 8 CHIMNEY PIPE INSTALLATION PG 4 5 6 9 TERMINATIONS PG 6 10 FINISHING YOUR FIREPLACE PG 7 11 MANTELS PG 7 12 GLASS DO...

Страница 3: ...will make installation easier 4 An outside air kit is included with this fireplace For more details refer to section on outside air kit installation on page 4 WARNING DO NOT INSTALL IN A BEDROOM MINIM...

Страница 4: ...28ga minimum to prevent corrosion STEP 6 Using screws or nails secure the fireplace to the framing through flanges located on the sides of the fireplace see figure 4 HEARTH EXTENSION A hearth extensi...

Страница 5: ...contents of these kits are listed under accessories on page 11 Most chimney systems for manufactured houses require a standard straight installation as described in this section If an uncommon offset...

Страница 6: ...it onto the firestop using holes provided see figure 10 The row of holes on the sides of the thimble is provided to allow for pitch variances Position the firestop assembly and thimble to desired angl...

Страница 7: ...but can be installed after the home is sited TERMINATIONS SPARK ARRESTOR The fireplace system must be terminated with the listed round top terminations In any case refer to the installation instructi...

Страница 8: ...16 from the wall the fireplace is installed in This combustible material can butt up against the side of the fireplace i e 1 from the fireplace opening OPERATING GUIDELINES AND MAINTENANCE INSTRUCTION...

Страница 9: ...ce cement Install the decorative gas appliance or cap off gas line if desired The gas pipe is intended for connection to an unvented vent free or a decorative gas appliance vented gas log If you wish...

Страница 10: ...d to rafters or joists see figure 22 details a b 3 Maximum length of pipe between supports return elbow or 12S 8DM is 6 of angled run Maximum of two 2 6 angled run sections per chimney system see figu...

Страница 11: ...to lock it in place see figure 25 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You m...

Страница 12: ...CPMH A ACB 8 vent kit 9 vent kit 9 vent kit 36 8DM 36 Double Wall Pipe 2 1 2 24 8DM 24 Double Wall Pipe 1 3 0 18 8DM 18 Double Wall Pipe 0 0 2 FST A Adjustable Firestop Thimble 1 1 1 6F 8 Roof Flashi...