background image

5

TUBE LOADING (cont'd)

5. Adjust tubing retainer. 

(Figure #4.)

Release the tubing retainer from its
locked position by pushing it slightly
into the body, then downward and
firmly against the tubing.

Repeat for both sides.

NOTE:

Tubing retainers usually do

not need to be readjusted when
changing tubing of the same type
and size.

NOTE:

There are a few combinations of tubing and materials that may require a

further adjustment of the tubing retainers if the tubing creeps. Open Pump Head,
move tubing retainer down one (1) notch, then close Pump Head. Turn pump on.
If tubing creep persists, repeat procedure.

MULTI-CHANNEL MOUNTING

L/S EASY-LOAD Pump Heads can be mounted in tandem (up to four) depending
upon the torque capabilities of the drive. 

(See Figure #5.)

Special mounting hardware is required. 

See REPLACEMENT PARTS AND ACCESSORIES for mounting hardware. 

CAUTION:

DO NOT OVERTIGHTEN SCREWS OR WING NUTS.

NOTE:

The L/S EASY-LOAD Pump Head can be used in any combination with

other L/S EASY-LOAD 

II

Pump Heads. The longer L/S EASY-LOAD 

II

mounting

hardware is required (not supplied).

NOTE:

The tubing on the inside L/S EASY-LOAD Pump Head(s) can be changed

without dismantling the outside Pump Head(s) from the drive.

Figure #4. Retainer Adjustment

Figure #5.

Multi-channel Mounting

Mounting Holes For

Tandem Units

Mounting Bolts

Содержание Masterflex S

Страница 1: ...8373 U S and Canada only 11 847 549 7600 Outside U S 847 549 7600 Local www masterflex com techinfo coleparmer com Thermo Fisher Scientific 1 800 637 3739 U S and Canada only 11 847 381 7050 Outside U...

Страница 2: ...the rotor is partially exposed when the LOADING LEVER is in the open position NOTE Use only MASTERFLEX precision tubing with MASTERFLEX pumps to ensure optimum performance Use of other tubing may void...

Страница 3: ...k outside this range with some possible reductions in performance or product life Pump Head no Pump Material Occlusion Shaft Length L S Tubing 07518 00 PSF CRS Fixed Short L S 13 14 16 25 17 18 07518...

Страница 4: ...UP The L S EASY LOAD Pump Head is compatible with most MASTERFLEX L S drives with a standard tang interface Mount the Pump Head using the 2 screws provided See Figure 1 TUBE LOADING 1 Be sure the pump...

Страница 5: ...f tubing creep persists repeat procedure MULTI CHANNEL MOUNTING L S EASY LOAD Pump Heads can be mounted in tandem up to four depending upon the torque capabilities of the drive See Figure 5 Special mo...

Страница 6: ...ution to clean the Pump Head Do not immerse nor use excessive fluid Disassembling Pump Head 1 Remove Pump Head from drive 2 Remove the two screws shown in Figure 6 Figure 6 Disassembling Pump Head 3 R...

Страница 7: ...no 07518 00 07518 08 07518 20 07518 28 07518 02 07518 09 07518 22 07518 29 07518 10 07518 18 07518 30 07518 38 07518 12 07518 19 07518 32 07518 39 07518 60 07518 68 07518 80 07518 88 07518 62 07518 69...

Страница 8: ...delays contact the seller or Manufacturer for authorization and shipping instructions before returning the product either within or outside of the warranty period When returning the product please st...

Отзывы: