background image

3

 INTRODUCTION AND GENERAL DESCRIPTION

The MASTERFLEX

®

 L/S

®

 COMPACT Pump Drives are designed as an inex-

pensive variable speed drive which accepts MASTERFLEX

®

 L/S

®

 STANDARD,

QUICK LOAD

®

 and EASY-LOAD

®

 Pump Heads. These 200 rpm drives ac-

commodate one Pump Head and one tube at controlled speed as low as
30 rpm. All units operate from an External Power Supply. The 115V AC and
230V AC models are supplied with an External Power Supply which provides
a DC output for connection to the Pump Drive.

Figure1. MASTERFLEX

®

 L/S

®

 Compact Pump Drive

The single-turn adjustable Speed Control, Figure 2, provides variable flow
operation. The green POWER On indicator lights whenever the pump is oper-
ating. The Power On/Direction Switch turns power on when either clockwise
or counterclockwise pump rotor direction is selected. The MAX Button is used
for priming and purging and operates the pump at maximum speed while
depressed.

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Содержание MasterFlex L/S 77200-00

Страница 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Страница 2: ...4 800 MASTERFLEX 627 8373 847 247 2929 FAX www masterflex com e mail techinfo coleparmer com A 1299 0742 Edition 03 OPERATING MANUAL COMPACT PUMP DRIVES MODEL NOS 77200 00 77200 10 77200 12 Artisan Sc...

Страница 3: ...turned off before proceeding Loose clothing could be caught in the drive EU Declaration of Conformity Name of Apparatus MASTERFLEX Compact L S Pump System Model Numbers 77200 00 10 12 Description of...

Страница 4: ...th an External Power Supply which provides a DC output for connection to the Pump Drive Figure1 MASTERFLEX L S Compact Pump Drive The single turn adjustable Speed Control Figure 2 provides variable fl...

Страница 5: ...bar For remote control by switch closure re move the shorting bar and connect the two terminals of an isolated remote control switch or relay to terminals 3 and 4 A closure of the remote switch contac...

Страница 6: ...the drive unit the mounting screws should only be tightened fingertight Excessive tightening of the mounting screws will result in binding and unsatisfactory performance Tubing Accepted The Pump Head...

Страница 7: ...e direction switch in the down position The POWER indicator should light and the fluid will flow from left to right To turn pump off place switch in the center position 6 The pump speed is controlled...

Страница 8: ...ct closure connection at terminal strips 3 and 4 Construction Dimensions L W H 5 750 in 5 14 in 4 14 in 14 6 cm 13 0 cm 10 5 cm Weight 1 88 pounds 0 85 kg Material Painted Steel Enclosure Rating IP22...

Страница 9: ...ced to you The warranty period for this product is noted on the Warranty Card PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for authoriza tion and shipping instructions...

Страница 10: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: