COLASIT AG
Plastic construction
CH-3700 Spiez
Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61
TD-000 675-E
Edition 10/2019, Subject to alteration
Copyright by COLASIT AG Spiez
Page 21
19.2
ATEX-Declaration of Conformity
ATEX-Declaration of Conformity
Equipment, components and protection systems for use for their intended purpose in explosion protected
zones
–
Directive RL 2014/34/EU (ATEX)
Document number :
TD-000 789
Product designation:
Pipe- / Roof plastic industrial fan CRDV 200-315
Hersteller:
COLASIT AG
Faulenbachweg 63
3700 Spiez
Product description
Plastic industrial fan fort he conveyance of chemically
aggressive gases, vapour or correspondingly contaminated air.
The conformity assessment process was conducted in compliance with Directive 2014/34/EU (ATEX).
The results are recorded in the confidential
Test Report TD-000 790
. All related documents are kept at the
centres named below:
QS Zürich AG, named centre CE 1254
Wehntalerstrasse 3
CH-8057 Zürich
COLASIT hereby certifies compliance with the basic health and safety requirements for the design and
manufacture of equipment and protection systems for use for their intended purpose in explosive
atmospheres in compliance with Annex II of the Directive.
The following harmonised standards were applied:
EN 1127-1: Explosive atmospheres
– Explosion protection, Part 1, 2011
EN ISO 80079-36: Non-electrical equipment for potentially explosive atmospheres, Part 36, 2016
EN ISO 80079-37: Non-electrical equipment for potentially explosive atmospheres, Part 37, 2016
EN 14986: Design of fans working in potentially explosive atmospheres, 2007
The marking on the appliance must comprise the following information:
II 3/-G Ex h IIB+H
2
T3 or T4 Gc/- (conveyed medium Zone 2, site of installation no Zone)
II 3/3G Ex h IIB+ H
2
T3 or T4 Gc (conveyed medium Zone 2, site of installation Zone 2)
II 2/3G Ex h IIB+ H
2
T3 or T4 Gb/Gc (conveyed medium Zone 1, site of installation Zone 2)
II 2/2G Ex h IIB+ H
2
T3 or T4 Gb (conveyed medium Zone 1, site of installation Zone 1)
The associated operating instructions contain important safety instructions and regulations for putting the
named equipment into operation in compliance with Directive 2014/34/EU (ATEX).
Changes to the named equipment are prohibited except with the manufacturer's express approval in writing.
If the named equipment is built into a higher level machine, the new risks ensuing from the integration must
be assessed by the manufacturer of the new machine.
Spiez, 31.10.2019
Andreas Roth
Urs Moser
Authorised representative for documentation
On behalf of the executive management