Part 1: General 

General 

 

OBLIGATIONS 
Prior to any work done on or with the fan, we place you under an obligation to 
read this operating manual and any 

further contractors’ operating instructions 

carefully and through to the end. 
Should anything not be clear, please get in touch with us immediately.  Do not put 
the fan into operation as long as uncertainties exist. 
As soon as you start up the fan you confirm that you have read and understood 
the operating manual.  

 

 

After acquainting yourself with the fan and its operational performance together 
with your production processes, we recommend that you make a note of the 
different modes of operation in a 

“process instruction”. 

 

 

 
Together with this operating manual, any acceptance documents, works acceptance certificates and the EU  
Declaration of Conformity, the process instruction forms part of the complete system documentation. 

For the fan, a separate risk analysis was conducted as a prerequisite for writing this operating 
manual. Risks were evaluated and any remaining residual risks are pointed out in this operating 
manual. 
 

When extracting aggressive gases, it is imperative to review the suitability of the 
materials: 
 
▪  Once the principal or the operator has notified us of the gas mix and the 

maximum operating temperature, the suitability and any applicable 
restrictions will be confirmed in the data sheet of COLASIT AG. 

 

▪  In the absence of a written notification with regard to the extracted 

medium by the principal, the operator is responsible without limitation 
for assessing the suitability for the operation of the ventilator. 

 

 

 

 

1.1 

Definition 

 

The term "COLASIT fan" stands for a Swiss high-quality product and contains all the components and 
individual parts as specified in the purchase order or in the material parts list, which, when assembled, form 
a functional unit. 
 

1.2 

Production of COLASIT-fans 

 

The fan was manufactured using modern production methods and was extensively tested both during 
manufacture and as a finished product by the COLASIT quality assurance system. The methods and 
processes used in production and monitoring correspond to the state of the art. The personnel entrusted 
with production of the fan have the appropriate skills and possess valid qualifications. 
All fans 

with engine are subjected to a successful test run at the manufacturer’s production facilities. 

 

1.3 

Warranty 

 

Warranty ends on the date stated in the general terms of sale and delivery. Warranty is limited to the 
delivery of spare parts or the repair of defe

ctive parts at the manufacturer’s factory. Any further claims or the 

replacement of non-repairable or wear parts are excluded.  
We guarantee the availability of spare parts identical in construction to the original over a period of 10 years 
effective from the date of delivery. 

Содержание CMV 450

Страница 1: ...ition 10 2019 Subject to alteration Copyright by COLASIT AG Spiez Page 1 OPERATION MANUAL CMV 450 800 Medium pressure Plastic industrial fan Agent For use in Ex zones Not for use in Ex zones COLASIT A...

Страница 2: ...deserves your full attention please read it carefully The contents of this operating manual are subject to change without notice in order to take technical progress into account The manual contains i...

Страница 3: ...tions EMERCENCY STOP 11 6 Operation 11 6 1 Safety instructions 11 6 2 Putting out of operation 11 7 Maintenance repair cleaning 12 7 1 Preparation 12 7 2 Performance 12 8 Spare parts 14 9 Operating in...

Страница 4: ...ator has notified us of the gas mix and the maximum operating temperature the suitability and any applicable restrictions will be confirmed in the data sheet of COLASIT AG In the absence of a written...

Страница 5: ...r damage nor that the fan will cause any damage 1 5 Personnel qualifications The fan may only be put into operation handled operated maintained and cleaned by trained personnel who are authorised and...

Страница 6: ...peration It may only be put into operation again when the safety devices are fully functional again Overpressure If the fan is operated in overpressure conditions with normal seals there is a danger o...

Страница 7: ...ng as the fan including all parts belonging to it or equipment connected to it has not been installed and checked out and until the operating manual has been read completely before commissioning We st...

Страница 8: ...ding terminal of the motor and fan must be connected to a potential equalization system Motors with protection type e are standard for using in the explosion proof design of our fans The standard vers...

Страница 9: ...ation item for item on this form The signed form must be kept by the safety officer or operating company COLASIT also offers a comprehensive installation service for fans 3 Shipping unpacking inspecti...

Страница 10: ...oise nuisance we recommend that the fan should not be installed in the immediate vicinity of workplaces 5 Commissioning initial startup test run The fan should only be put into operation after inspect...

Страница 11: ...ch in the vicinity of the emergency exit Please request confirmation from an in house electrician that the electrical installations were carried out and tested in accordance with regulations that all...

Страница 12: ...smooth running of the fan and electric motor Check state and tension of the V belt and replace if necessary Check the impeller and casing for deposits and clean if necessary Check the shaft bearing f...

Страница 13: ...ich are not intended for repair by the operator must be sent to the manufacturer or agent for repair or replacement e g damaged impeller Your agent or COLASIT also offers customer services Manufacture...

Страница 14: ...process instructions in various chapters of this operating manual To help ensure the safe operation of the fan COLASIT offers the service of reviewing process instructions prepared by the operator 10...

Страница 15: ...ten if necessary Foreign bodies or soiling in grooves or pulleys Clean pulleys and check belt profile Leak at shaft bushing Seal not suitable for application Consult the manufacturer Leak on sleeves S...

Страница 16: ...1 Manufacturer 2 Field for CE marking and applicable standards 3 ATEX identification for details see the section on Explosion Protection 4 Fan specifications fan type casing design material of casing...

Страница 17: ...on CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 796 E Edition 10 2019 Subject to alteration Copyright by COLASIT AG Spiez Page 17 16 Dimensional drawings 16 1 Dimensions of the C...

Страница 18: ...c construction CH 3700 Spiez Phone 41 0 33 655 61 61 Fax 41 0 33 654 81 61 TD 000 796 E Edition 10 2019 Subject to alteration Copyright by COLASIT AG Spiez Page 18 16 2 Dimensions of the CMV 450 800 w...

Страница 19: ...s 17 1 Assembly instructions for CMV 450 800 with direct drive 1 Attach support steel sheets including round steel plate and motor to base frame 2 Place plastic back plate and impeller onto shaft with...

Страница 20: ...20 17 2 Assembly instructions for CMV 450 800 with V belt drive 1 Attach support steel sheets including round steel plate pedestal bearing and shaft to base frame 2 Place plastic back plate and impel...

Страница 21: ...1 Fax 41 0 33 654 81 61 TD 000 796 E Edition 10 2019 Subject to alteration Copyright by COLASIT AG Spiez Page 21 5 Mount sliding rails steel part of V belt protection and V belt drive 6 Mount V belt a...

Страница 22: ...t to alteration Copyright by COLASIT AG Spiez Page 22 18 Spare parts lists 18 1 Spare parts list for CMV 450 800 with direct drive 1 Support 1 Base frame 7 Back plate 2 Support construction 8 Impeller...

Страница 23: ...for CMV 450 800 with V belt drive 1 Base frame 11 Support bracket 2 Support construction 12 Front steel plate 3 Motor plate with bracket 13 Base rails 4 Pedestal bearing 14 Sliding rails 5 Shaft 15 Mo...

Страница 24: ...or number and date of issue of the standard s 2006 42 EG Maschinensicherheit 2006 42 CE S ret des machines 2006 42 EC Machinery safety EN ISO 12100 2011 EN ISO 13857 2008 EN 60204 1 2019 2014 30 EU E...

Страница 25: ...ith Annex II of the Directive The following harmonised standards were applied EN 1127 1 Explosive atmospheres Explosion protection Part 1 2011 EN ISO 80079 36 Non electrical equipment for potentially...

Страница 26: ...1 2 an explosion proof motor with temperature class T4 must be fitted If an explosion proof motor with temperature class T3 is used temperature class T3 shall apply to the entire fan Ambient temperatu...

Страница 27: ...o alteration Copyright by COLASIT AG Spiez Page 27 19 3 Further certificates This operating manual has the following certificates enclosed Datasheet of the fan If ATEX version additionally ATEX Certif...

Страница 28: ...are connected close to the fan With free intake blow off fans a protective grating with a mesh width of 10mm is fitted The clearance between the impeller and the casing is min 5mm and max 20mm All ro...

Отзывы: