Signalling
Fault
Possible causes
Cures
AL 8
NO NEG
PRESS
-In the work stage the stove
detects a pressure below the
vacuum switch setting threshold.
-The system is stopped.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty vacuum switch.
-Check cleanness of the fume
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the
overpressure valves.
-Other reinstatement operations
must be carried out by a service
centre.
AL 9
INSUFF
DRAUGHT
-Appears when the combustion
air flow is below a certain
threshold.
-The combustion chamber is dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-Check cleanness of the fume
duct and combustion chamber.
-Check hermetic closing of the
door.
-Check
closing
of
the
overpressure valves.
-Other reinstatement operations
must be carried out by a service
centre.
AL E
WATER
PRESSURE
-Occurs when the water pressure
does not come within the values
for correct operation.
-The system is stopped.
-Occurs when the pressure
transducer on the water circuit
detects a pressure below 0,6 bar
or above the fixed limits.
-Check the cause of the problem,
restoring the circuit pressure by
bringing it to the normal operating
value.
AL c
WATER
PROBE
-Occurs in case of a water
temperature probe fault.
-The shutdown procedure is
activated.
-Faulty probe
-The probe is disconnected from
the board.
-Reinstatement operations must
be carried out by a service centre.
AL d
HOT
WATER
-Occurs when the water
temperature has exceeded the
fixed limits.
-The system is stopped.
-Occurs when the temperature
probe in the heating chamber
detects a value above 92°C.
-Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
WAITING
COOL
-Occurs on relighting the stove
immediately after having shut it
down.
-Reset attempt in shutdown stage
with stove hot in cooling stage.
-Alarm reset is possible only after
shutdown.
AIR FLOW
METER
FAILURE
-Occurs when the air flow meter is
disconnected.
-The controller does not detect
the quantity of combustion air
and does not shut down the
stove; it only excludes the air
flow meter functions.
-Reinstatement operations must
be carried out by a service
centre.
FROST RISK
-Occurs when the water
temperature falls below a certain
value.
-The stove control detects the
water temperature below 6°C
and displays a message.
-The pump starts in order to move
the water inside the heating
circuit.
- Monitor the water temperature
so that it does not fall below 0°C.
SERVICE
DUE
-Occurs when the stove has
exceeded 1800 hours of
operation or 2000 Kg pellet,
since the previous servicing.
-Extraordinary
maintenance
notice.
- Cleaning - extraordinary
maintenance and reinstatement
operations must be carried out by
a service centre.