4. Motor rotation direction and phase sequence measurement
Voltage Measurement Function.
In ACV mode, main display shows ACV value, the secondary display shows frequency.
Short press "SELECT" button to enter L-Pass Filter function, main display shows voltage
value and the secondary display shows frequency.
In ACV voltage mode, long press SELECT button for more than 2 seconds to enable
motor rotation direction function. Main display shows the current voltage value and the
secondary display shows operation frequency.
When resting Motor function, short press SELECT button once to enable phase sequence
measurement.
Long press SELECT button (more than 2 seconds) to exit Motor function.
Steps: Phase sequence measurement (Detection condition: Above AC 80V, frequency is
40Hz to 80Hz, and it will keep on waiting if the range is exceeded).