Coiltek CS-5000 V2 Скачать руководство пользователя страница 16

14 

 

 Cable Connections 

 
The two boards in the CS-5000 V2 and CS-5100 V2 controls are connected by nine-conductor cable.  
The colored wires on each end of the cable are connected in the same order, the only difference being 
that one end of the cable will have longer green and brown wires than the other.  This end of the cable 
will connect to the range card with the longer wires connecting to the LED mounted in the endcap of 
the boom.  Please follow the diagrams below to wire your unit. 
 
 

Range Card & Endcap 
 

 

 
 

Features of the CB-5101R-2 Range Card 

This latest update of the Coiltek range card is form, fit and function compatible with the 
CB-5101R, CB-5101R-1 versions (above).  All installation procedures and precautions associated with 
previous versions apply, including removal of the 7 pin connector (above). 
 
The sensitivity potentiometer, which governs the amount of echo received, has been repositioned such 
that adjustment may be made by removing the case end cap (figure below).  On previous cards, this pot 
was mounted flat so that adjustment required removing the card from the case or stand boom.  Adjust 
clockwise to increase sensitivity, counterclockwise to decrease. 
 

 

 

 
 
 

Содержание CS-5000 V2

Страница 1: ...OPERATING MANUAL CS 5000 V2 6676 Millersburg Road Wooster OH 44691 Tel 800 883 7542 330 601 1350 Fax 330 601 1352 Email info coiltek com Website www coiltek com...

Страница 2: ...ck Loop Control 3 Notes on Slack Loop Control 4 Manual Set Up 5 Extending Upper Limit 7 Offset 8 Remote Access to Presets 9 Terminals and Inputs 10 DIP Switch Functions 11 STOP Input 13 Cable Connecti...

Страница 3: ...rasonic transduction is fairly straightforward A burst of acoustic energy is broadcast toward the target the loop valley Milliseconds later the transducer is switched to receive mode to await the echo...

Страница 4: ...0 and 240VAC The supply requires only L1 and L2 Connect incoming ground to the subpanel or enclosure The CS 5000 may be ordered without the supply LPS when a 24VDC source of sufficient amperage is ava...

Страница 5: ...device to accelerate or decelerate In the diagrams above it s clear that the deeper U shaped loop develops the most free material between long and tight loop avoiding the generally undesired tight loo...

Страница 6: ...move over time Speed of Response Most slack loop control applications govern variable speed powered follower machinery When this is the case a well proportioned loop will yield better performance if...

Страница 7: ...Calibration is complete Alternately 1 Press button S1 Lights above buttons S2 and S3 will begin to blink 2 Put a target beneath the sensor Place it in the desired near position It will be the upper l...

Страница 8: ...anspire Set up of this feature is described below Auxiliary Relays The CS 5000 has two auxiliary relays that may be programmed to fire anywhere in the set control range To set them up Turn ON DIP swit...

Страница 9: ...and minimizing nuisance stoppage To use this feature press the S2 and S3 buttons simultaneously This causes the unit to enter a near relay setup mode indicated by LEDs above S2 and S3 turning on Place...

Страница 10: ...t of the control jumps to 2 5 VDC when the loop crosses the long loop limit into the control range The discontinuity in the output may be useful when the follower machinery must start rapidly Since th...

Страница 11: ...y the DIP switches are used for manual programming of the system Then they are all turned off and the remote switches or contacts access the presets via the header at P4 Since the DIP switches and the...

Страница 12: ...10 Terminals and Inputs...

Страница 13: ...on of the control range The signal increases as the target gets closer to the sensor This behavior is associated with the control of machinery that feeds a process such as a decoiler With SW7 ON the o...

Страница 14: ...on of the ranging card with the main processor card is as follows The main board emits a START pulse The range card replies with two consecutive pulses the first is a START acknowledge pulse the secon...

Страница 15: ...he sensor at the position at which you d like the relay to make Press button S1 Lights over buttons S2 and S3 will blink To set the K1 leftmost relay press S3 To set K2 2nd left relay move the positio...

Страница 16: ...unit Range Card Endcap Features of the CB 5101R 2 Range Card This latest update of the Coiltek range card is form fit and function compatible with the CB 5101R CB 5101R 1 versions above All installati...

Страница 17: ...15 Mainboard...

Страница 18: ...driver and use the mchpcdc cat driver downloaded A new version of our software CSWin64 is under development When available it will be posted in the downloads section of coiltek com Adjusting Unit Sens...

Страница 19: ...Its attachment to the system will cause manual programming to become unavailable 2 The above may result in the need for a new connection harness as the pin out has changed If you should need assistan...

Страница 20: ...______________________________________________________________ ___________________________________________________________________________________ _____________________________________________________...