3950 SERIES iVIEW
CAMERA/POSITIONER SYSTEM

Installation and Operation Manual

COHU, INC. ELECTRONICS DIVISION

Figure 1. iView

COHU

Cohu Inc., Electronics Division

Содержание 3950 SERIES iVIEW

Страница 1: ...nada San Diego CA 92123 1827 Phone 858 277 6700 FAX Email info cohu com WEB www cohu cameras com 858 277 0221 August 12 2005 3950 SERIES iVIEW CAMERA POSITIONER SYSTEM Installation and Operation Manua...

Страница 2: ...0 GENERAL DESCRIPTION 4 1 1 Electrical Characteristics 4 1 2 Mechanical Characteristics 4 2 0 INSTALLATION 5 2 1 Unpacking and Receiving Inspection 6 2 2 Static Discharge Protection 6 2 3 Equipment Su...

Страница 3: ...0 Hz Power Connsumption 50 Watts with camera heaters on camera and positioner Communications Opto isolated serial port RS 422 with digital position feedback RS 232 and RS 485 available Protocol Non pr...

Страница 4: ...ailure all 64 preset positions of all Positioners are stored in nonvolatile memory Each iView address within a surveillance system can be selected electronically from the Monitoring Center There are n...

Страница 5: ...e 2 0 INSTALLATION An iView can typically mounted in any one of three mechanical configurations depending on the mount ing accessories supplied This is determined by the model number 1 Pedestal Mount...

Страница 6: ...rms for filing the con cealed damage claim 2 2 STATIC DISCHARGE PROTECTION Procedures in this manual do not require entry into the housing of the positioner camera However in the event that an open un...

Страница 7: ...ITIONER THROUGH CONDUIT TO CONTROL EQUIPMENT Figure 3 Typical Pedestal Mount Installation Positioner Small Pedestal Baseplate PEDD Dimensions Positioner with 34 inch pigtail and connector Dimensions o...

Страница 8: ...h the four holes spaced 90 degrees apart Farther out from that pattern is a 7 25 inch diam eter pattern displaced by 22 720 degrees from the first pattern This pattern also consisting of four holes sp...

Страница 9: ...g a pole mount depends the situation encountered It can either be directed down behind the pole bracket or if arrangements have been made for this into the pole Junction boxes drip loops and weather p...

Страница 10: ...ach to Positioner cable NOTE Arm is typically shipped with Adapter Plate attached POSITIONER CABLE Route through Adapter Plate into Arm POLE Figure 6 Typical Pole Mount Installation Typical Installati...

Страница 11: ...ttern is on a standard 4 75 inch diameter circumference Proceed as follows for installation on a pedestal 1 Route the cable pigtail down into the pedestal This cable should be secured by a strain reli...

Страница 12: ...he wall mount arm Continue the cable through the arm and out the hole at the iView mounting location 4 Install a weather tight gasket between the arm and the surface of the wal if required 5 Bolt the...

Страница 13: ...w is desired for setup and maintanance operations NOTE The video line must be terminated with 75 ohms for proper operation iVIEW F O Cable 115 V ac Version 422 Alternate Serial Port 232 Serial Port Ca...

Страница 14: ...w on the adapter plate and install the stainless steel hardware grade 316 7 Verify that the iView will have a full range of movement without striking any nearby structure 8 Proceed to section 2 10 to...

Страница 15: ...ving a terminal strip for all connections This cable has five stripped wire leads for the data connections and also stripped leads for the ac power plug BNC video connector Figure 12 is the assembly d...

Страница 16: ...w Figure 16 shows a typical 232 422 converter The terminal labels used on various models of these converters differ so it is important to read the literature accompanying the converter being used Note...

Страница 17: ...overnment supply channels as GSA Schedule GS 07F 5739R This material is a thick tape like material sepa rated by a paper divider in its roll to prevent bonding to itself before use After this material...

Страница 18: ...ms with mul tiple iView when the central control is a Net Cams Server 2 10 1 Win MPC Setup When Win MPC figure 17 is used to set up the iView it must be isolated from all other iViews in the system Th...

Страница 19: ...RS 232 output of a PC to RS 422 for communications with an iView during field setup and testing A local PC with Win MPC software typically is used in this application If this converer is plugged into...

Страница 20: ...16 NOT USED 1 3 7 8 9 4 5 6 2 16 15 11 12 13 14 10 Figure 17 Typical Win MPC Application addresses at a test bench located at the central distribution location prior to sending each of them out to the...

Страница 21: ...in MPC to search for the existing iView address This will verify that communications has been estab lished Click on the FIND button at upper left of the screen A pop up window will appear while Win MP...

Страница 22: ...been established with the iView various functions should be tested to verify proper operation A test stand pedestal figure 20 is available on which to mount the Positioner during this testing phase U...

Страница 23: ...number on the outside of the shipping container s and on paperwork contained inside Give a brief description of why the equipment is being returned and list the symptoms of any problems being experien...

Страница 24: ...cations within one month of delivery shall be repaired without charge This warranty does not extend to Cohu equipment subjected to misuse accident neglect improper application or repaired or altered b...