MPORTANT

 

To operate in Multi Chassis Mode, additional hardware modules are 

required. The Chassis Mode can be changed at any time, so it is 

recommended to select SingleMode until all other configuration 

requirements have been met. 

 

8.

 

Installation will continue and then you will be presented with the Chassis Mode 
options. 

 

9.

 

Once complete, reboot the Chassis. 

 

 

Содержание SwitchPXIe Series

Страница 1: ...SwitchPXIe Optical Switch USER MANUAL...

Страница 2: ...urate and reliable However no responsibility is assumed by Coherent Solutions for its use nor for any infringements of patents or other rights of third parties that may result from its use No license...

Страница 3: ...Input 10 Cleaning and Connecting Optical Fibers 10 5 Handling the SwitchPXIe Module 11 SwitchPXIe Module Installation 11 SwitchPXIe Module Uninstallation 13 6 Software Installation Information 14 Ins...

Страница 4: ...Descriptions 46 13 5 1 Slot Commands 46 13 5 2 Configuration Commands 47 Multi Chassis Mode Operation 48 13 6 1 NI MAX 48 13 6 2 SCPI Multi Chassis Commands 49 14 Maintenance 50 15 Technical Support 5...

Страница 5: ...ry Do not proceed unless the required conditions are met and understood CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Do not proceed u...

Страница 6: ...dures other than those specified herein may result in exposure to hazardous situations or impair the protection provided by this unit CAUTION The SwitchPXIe modules are sensitive to electrostatic disc...

Страница 7: ...witch ensures repeatable and low loss switching to various test set ups while taking advantage of the PXIe mainframe s flexible connectivity and high channel density form factor SwitchPXIe Overview Fe...

Страница 8: ...Double Slot Models Note Number of common and routing ports will depend on the selected model SwitchPXIe 1106 shown above 1 Fastening screw 2 Error Status LED 3 Common Optical port 4 Routing Optical p...

Страница 9: ...ng Indicator LEDs 3 Red Optical ports 4 Blue Optical ports 5 PXIe Module Optical Connector Information 6 Fastening clip 7 SwitchPXIe Module Information 8 PXIe Headers IMPORTANT All Crossover switch mo...

Страница 10: ...ost often this means an invalid route position 3 4 2 For SwitchPXIe 1006 1009 1107 Blinking yellow Indicates initialization on startup Solid green Indicates successful initialization and communication...

Страница 11: ...ropyl alcohol b Use compressed air to dry completely c Visually inspect the fiber end to ensure its cleanliness 3 Carefully align the connector and port to prevent the fiber end from touching the outs...

Страница 12: ...Please be sure to wear a grounded wrist strap at all times when handling the SwitchPXIe module to prevent such damage Take care not to handle the connectors on the SwitchPXIe module as once they are e...

Страница 13: ...he module are properly connected to the chassis 6 Secure the module into the chassis by pulling up on the black locking clip A click should be heard when the locking clip is properly engaged into the...

Страница 14: ...s enough time to finish boot procedures and initialize the communication server 1 Shutdown the PXIe chassis 2 Unfasten the locking clip on the SwitchPXIe module Unscrew the fastening screw Pull out th...

Страница 15: ...stallation Overview The following is an installation guide of the minimum required NI and CSL resources to install so that the CSL Modules can be used 1 Install the CSLDriverInstaller Software Package...

Страница 16: ...t 1 Locate installer setup exe in the CSLDriverInstaller folder on the provided media 2 Allow installation by clicking Yes in the User Account Control prompt and proceed with installing the NI CSL Dri...

Страница 17: ...tch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 16 5 Select the Always trust software from National Instruments Corporation option to allow uninterrupted installation 6 Disabling Windows fas...

Страница 18: ...down the Chassis Install the desired CSL PXIe Modules into the Chassis now 8 Once the new modules are installed turn on the Chassis The Chassis will now install the new drivers for the installed modul...

Страница 19: ...ant interface 1 Locate the CSLServer x x x win32 exe installer and run this as Administrator you will be prompted Allow installation by clicking Yes in the UAC prompt 2 If a previous version of the CS...

Страница 20: ...ch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 19 4 Proceed with installation by accepting Licence Agreement 5 Recommended Leave the default settings for adding the CSLServer installation lo...

Страница 21: ...Optical Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 20 6 Recommended Accept the default installation destination for the CSLServer package 7 Choose the location of the shortcuts in t...

Страница 22: ...ssis Mode additional hardware modules are required The Chassis Mode can be changed at any time so it is recommended to select SingleMode until all other configuration requirements have been met 8 Inst...

Страница 23: ...within a web style application 1 Run the cohesionUI installation with Administrator privileges If there is an installation of a previous version of CSLWebServer present the cohesionUI application wil...

Страница 24: ...latform Optical Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 23 2 Proceed with installation by accepting the License Agreement 3 Click Next at the Welcome screen to continue the instal...

Страница 25: ...cal Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 24 4 Recommended Select the Apache option for the web server installation 5 Recommended The dependencies are automatically selected for...

Страница 26: ...Ltd Version 2 01 25 6 Recommended Click Install to begin the installation in the default location 7 While installing the required resources other installers will show progress as they are called These...

Страница 27: ...Ie Platform Optical Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 26 8 Apache When installing and configuring the Apache service you will be required to allow the firewall rules IMPORTA...

Страница 28: ...9 Recommended Once the file copy progress is complete you will require to select a port number for the cohesionUI to use 10 Once selected you will be prompted if the port number chosen is not availab...

Страница 29: ...PXIe Platform Optical Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 28 11 Once completed please reboot the Chassis to enable all the services to restart automatically...

Страница 30: ...to simplify installation of new Firmware onto the CSL PXIe Modules The Firmware Updater is installed as part of the CSLServer package An icon will be installed in the start menu to allow easy access t...

Страница 31: ...d bex firmware file must be downloaded from the Coherent Solutions website 1 Go to https www coherent solutions com resources pxi 2 Find and download the relevant Firmware file Running the CSL Firmwar...

Страница 32: ...3 Select the Chassis Mode from the toggle button If operating in MULTI mode then the Chassis drop down will be available to edit If operating in SINGLE mode the Chassis drop down will be greyed out By...

Страница 33: ...sired file 5 Once all valid selections have been made the Update button will be enabled IMPORTANT The Update procedure will stop the CSLServer All connections to the instrument will be lost Click the...

Страница 34: ...ess bar will show the status of the update Any error codes will also be displayed in the information panel below the progress bar 7 During the user selections and primarily after the Update process ha...

Страница 35: ...er selections will be displayed in the information panel The error code displayed will remain until a new update process has been started The given example shows the error code from an incorrect inval...

Страница 36: ...s can either be accessed via remote or local means Local access is achieved by running cohesionUI on the embedded PXIe controller module in the chassis Remote access can be achieved from any compatibl...

Страница 37: ...g page of cohesionUI is called the Home page It will display a graphical representation of the module arrangement in the PXIe chassis The blue numbers beside each module show the slot in which they ar...

Страница 38: ...the controls for a given module click on the Modules tab Alternatively hovering over the Modules button will bring up a floating dropdown of the modules installed in the chassis Controls for a specifi...

Страница 39: ...clicking the button Both of these actions will allow access to the units displayed in the module controls Note Whenever the chassis is power cycled cohesionUI will revert back to default unit values...

Страница 40: ...01 39 Info The Info button can be clicked at any time to pull up a display bar on the right side of the screen This will show the chassis mode manufacturer model serial number of the chassis the cohe...

Страница 41: ...Modules menu button on the left will bring up a dropdown that the SwitchPXIe module can also be selected from After clicking the desired SwitchPXIe module its control page is displayed All informatio...

Страница 42: ...d port click the Port number eg PORT 2 The SwitchPXIe can route the light very quickly however cohesionUI takes a few seconds to update the displayed routing Therefore there is a slight delay between...

Страница 43: ...e CSLServer Parameter Default Unit Alternative Units Power DBM DBM Frequency HZ THZ GHZ MHZ KHZ Frequency Fine HZ THZ GHZ MHZ KHZ Wavelength NM M PM Argument Data Format wsp Specifies whitespace chara...

Страница 44: ...module this is an integer 1 to 18 m is the channel index of a specific unit in the module this is an integer 1 2 Message Queues Information is exchanged in the form of messages These messages are held...

Страница 45: ...oherent Solutions CSLServer PXIE 8133 FW2 0 15 Command OPC Syntax OPC Description Query the Operation Complete Status Parameters None Response 1 is returned if all the modules installed in the chassis...

Страница 46: ...omplete bit Query the modules installed on the slot Query the Identifier for the slot returns the manufacturer part number serial number hardware and firmware versions Configuration commands Descripti...

Страница 47: ...rameters None Response The response will be a comma separated string of detectors installed in the SwitchPXIe If a module is not installed in a channel it will not return any identification string Exa...

Страница 48: ...the error status of the specified channel of the SwitchPXIe Parameters None Response 1 Switch reporting an error 0 No error on switch Example ROUT1 CHANA ERROR 0 Command ROUTe n CHANnel m STATE Syntax...

Страница 49: ...PXIe 8834 to PXIe 8381 connection Chassis 2 has the controller running CSLServer and Chassis 3 is the extended chassis IMPORTANT The CSLServer does not manage the chassis numbers These are controlled...

Страница 50: ...is will always return 1 Example In Single chassis mode SYSTEM CHASSIS 1 SYSTEM CHASSIS LIST 0 SYSTEM CHASSIS MODE SINGLE In Multi chassis mode SYSTEM CHASSIS 2 SYSTEM CHASSIS LIST 2 3 SYSTEM CHASSIS M...

Страница 51: ...rature in a clean and dry area Keep the unit out of direct sunlight Avoid high humidity or significant temperature fluctuations Avoid unnecessary shocks and vibrations If any liquids are spilled on or...

Страница 52: ...cates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 SJ T11363 2006 Part Name Toxic o...

Страница 53: ...PXIe Platform Optical Switch Module SwitchPXIe Coherent Solutions Ltd Version 2 01 52 KCC INFORMATION Product KCC Registration No Logo SwitchPXIe XXXX XX R R Csn SwitchPXIe...

Страница 54: ...he name and the serial number see the product identification label as well as a description of your problem close at hand You may also be requested to provide software and module version numbers This...

Страница 55: ...PURPOSE IN NO EVENT SHALL COHERENT SOLUTIONS BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES Liability Coherent Solutions shall not be liable for damages resulting from the use of the produc...

Страница 56: ...pment for service or repair 1 Contact Coherent Solutions contact details are on the back cover Support personnel will determine if the equipment requires service repair or calibration 2 If possible ba...

Страница 57: ...2 01...

Отзывы: