PXIe Platform Photonic Doppler Velocimetry 

|

 

DopplerPXIe 

 

Coherent Solutions 

|

 

 

 

2

 

Safety Information 

 

W

ARNING

 

 

Do not install or terminate fibers while a light source is active. Care 
must be taken to ensure that the instrument has been turned OFF

 

before inspecting the end face(s) of the instrument, or any optical 
patch cords connected to this instrument. Never look directly into a live 
fiber and ensure that your eyes are protected at all times. 

 

 

The use of controls, adjustments and procedures other than those 
specified herein may result in exposure to hazardous situations or 
impair the protection provided by this unit. 

 

 

 

C

AUTION

 

 

The DopplerPXIe modules are sensitive to electrostatic discharge (ESD). 
Please be sure to store the modules that are not installed in protective 
electrostatic packaging. 

 

 

 

I

MPORTANT

 

 

For electromagnetic compatibility, this instrument is a Class A product. 
It is intended for use in an industrial environment. There may be 
potential difficulties in ensuring electromagnetic compatibility in other 
environments, due to conducted as well as radiated disturbances.

 

 

When you see the 

 symbol on your unit, make sure that you refer 

to the instructions provided in your user documentation. Ensure that 
you understand and meet the required conditions before using your 
product.

 

 

 

 

Содержание DopplerPXIe

Страница 1: ......

Страница 2: ...ccurate and reliable However no responsibility is assumed by Coherent Solutions for its use nor for any infringements of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent rights of Coherent Solutions The information contained in this publication is subject to change without notice Trademarks Coherent Solutions t...

Страница 3: ...Installation 10 6 Handling the DopplerPXIe Module 18 6 1 DopplerPXIe Module Installation 18 6 2 DopplerPXIe Module Uninstallation 20 7 Programming Guide 21 7 1 Programming Conventions 21 7 2 Specific Command Summary 22 7 3 Specific Command Descriptions 22 7 3 1 Slot Commands 22 7 3 2 Configuration Commands 23 8 Maintenance 28 9 Technical Support 30 9 1 Contacting the Technical Support Group 30 9 2...

Страница 4: ...ry Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in component damage Do not proceed unless you understand and ...

Страница 5: ...osure to hazardous situations or impair the protection provided by this unit CAUTION The DopplerPXIe modules are sensitive to electrostatic discharge ESD Please be sure to store the modules that are not installed in protective electrostatic packaging IMPORTANT For electromagnetic compatibility this instrument is a Class A product It is intended for use in an industrial environment There may be pot...

Страница 6: ...l components for PDV measurements in a single slot PXIe module to enable compact inexpensive and robust Photonic Doppler velocimetry measurement 3 1 Overview Features 1 Fastening screw 2 Status LEDs 3a Optical Probe Input Output port 3b Optical Target Input port 3c Optical Reference Input port 3d Optical Signal Output port 4 Optical Connector Information 5 Fastening clip 6 PXIe Headers ...

Страница 7: ... will pass through the circulator and be directed to the optical attenuator and inline power meter The Reference laser passes though an optical attenuator and inline power meter The Reference laser and the Probe input are coupled to the Output port through a 10 90 coupler respectively Through this configuration independent control of the Probe power and the Reference power is achieved The Power Me...

Страница 8: ...th a lint free swab dipped in isopropyl alcohol 2b Use compressed air to dry completely 2c Visually inspect the fiber end to ensure its cleanliness 3 Carefully align the connector and port to prevent the fiber end from touching the outside of the port or rubbing against other surfaces If your connector features a key ensure that it is fully fitted into the port s corresponding notch 4 Push the con...

Страница 9: ...hassis The CSLServer is installed as a service to auto start when the chassis is powered on 5 1 CSL Driver Installation Windows 7 1 Locate installer setup exe in the CSLDriverInstaller folder on the provided media 2 Allow installation by clicking Yes in the User Account Control prompt 3 Proceed with the NI CSL Driver installation and accept Licence Agreements ...

Страница 10: ...PXIe Platform Photonic Doppler Velocimetry DopplerPXIe Coherent Solutions 7 ...

Страница 11: ...PXIe Platform Photonic Doppler Velocimetry DopplerPXIe Coherent Solutions 8 ...

Страница 12: ...stall the CSL PXIe Modules into the Chassis 5 Once the new modules are installed power back on the Chassis The Chassis will now install the new drivers for the installed modules and you are able to install the CSLServer VXI11 service to the Chassis see the following section The modules will show up in device manager as CSL Devices ...

Страница 13: ...t Solutions 10 5 2 CSL Server Installation Windows 7 1 Locate the CSLServer x x x win32 exe installer and run this as Administrator you will be prompted 2 Allow installation by clicking Yes in the UAC prompt 3 Proceed with installation accepting Licence Agreement ...

Страница 14: ...PXIe Platform Photonic Doppler Velocimetry DopplerPXIe Coherent Solutions 11 ...

Страница 15: ...PXIe Platform Photonic Doppler Velocimetry DopplerPXIe Coherent Solutions 12 4 Once complete please reboot the Chassis ...

Страница 16: ...SLWebServer Installation Windows 7 1 Locate the CSLWebServer X XX XX x64 exe installer and run this as Administrator you will be prompted 2 Allow installation by clicking Yes in the UAC prompt 3 Proceed with the installation clicking I accept when the License Agreement prompt pops up ...

Страница 17: ...c Doppler Velocimetry DopplerPXIe Coherent Solutions 14 4 Select the type of web server for the setup If you are already running an IIS service then proceed with this option For all other users we recommend choosing Apache ...

Страница 18: ...PXIe Platform Photonic Doppler Velocimetry DopplerPXIe Coherent Solutions 15 5 Select the install location for the server ...

Страница 19: ...he Windows Defender Firewall prompt pops up select Private networks and click Allow access 7 Port numbers less than 1024 are reserved Input an available port number larger than 1024 and click Next If you enter in an invalid or assigned port you will be prompted to re enter a port number ...

Страница 20: ...oppler Velocimetry DopplerPXIe Coherent Solutions 17 8 Once complete reboot the Chassis for the installation to complete Note After reboot allow a few minutes for the WebServer to start up and initialise all necessary services ...

Страница 21: ...to wear a grounded wrist strap at all times when handling the DopplerPXIe module to prevent such damage Take care not to handle the connector on the DopplerPXIe module once they are exposed as this may leave corrosive residue which can damage the connector 1 Shutdown the PXIe chassis 2 If present remove the current module or blanking plate in the intended installation slot 3 Carefully remove the D...

Страница 22: ...module are properly connected to the chassis 6 Secure the module into the chassis by pulling up on the black locking clip A click should be heard when the locking clip is properly engaged into the front chassis rail Secure the fastening screw with a screwdriver 7 Perform a visual check to ensure no loose items or tools have been left in the chassis after installation Power on the PXIe chassis ...

Страница 23: ...nough time to finish boot procedures and initialize the communication server 1 Shutdown the PXIe chassis 2 Unfasten the locking clip on the DopplerPXIe module Unscrew the fastening screw Pull out the module from the chassis while firmly gripping the front plate edges of the DopplerPXIe module DO NOT PULL THE MODULE OUT BY GRIPPING ANY OF THE CONNECTORS 3 Insert the DopplerPXIe module in the antist...

Страница 24: ...ing VALUE1 VALUE2 This is a parameter choice The separates the unique parameters available only one of the choices can be used In the example you can use the input parameter VALUE1 or VALUE2 not both Some commands may have more than two choices available This parameter can be omitted where the command has a default defined in the command description Index Addressing of Modules slot source and VOA ...

Страница 25: ...uery the constant power output Set or query the output power averaging time Starts dark power nulling Set or query the output power offset Query the Trace buffer Query the status of the Trace Complete bit Set or query the number of trace buffer data elements Set or query the trace buffer sampling rate Triggering of the trace sampling 7 3 Specific Command Descriptions 7 3 1 Slot Commands Command SL...

Страница 26: ...NTrol n CHANnel m MODE Description Query the control mode Parameters None Response Returns a string non abbreviated of the current control mode for the specified channel Example CONT1 CHAN1 MODE ATTENUATION Command INPut n CHANnel m WAVelength Syntax INPut n CHANnel m WAVelength wsp value NM M MM UM PM Description Set the optical wavelength configuration Parameters value Set to the user wavelength...

Страница 27: ...efault Response None Example INP1 CHAN1 ATT 5 0 Command INPut n CHANnel m ATTenuation Syntax INPut n CHANnel m ATTenuation wsp MIN MAX DEF SET ACT ALL Description Query the attenuation Parameters MIN Return the minimum programmable value MAX Return the maximum programmable value DEF Return the default programmable value SET Return the current set value ACT Return the current value ALL Returns all ...

Страница 28: ...TPut n CHANnel m POWer AVERagingtime Syntax OUTPut n CHANnel m POWer AVERagingtime wsp MIN MAX DEF value S MS US NS Description Set the output power averaging time Parameters MIN Set to the minimum programmable value MAX Set to the maximum programmable value DEF Set to the default programmable value value Sets the averaging time to the user value in the specified units seconds are default Response...

Страница 29: ...er should wait for OPC to become ready before reading this Note this command will error out if no sample points have been triggered Parameters None Response Comma separated list of values for each channel and new line ie n separated rows per sample Example OUTP2 TRACE1 POINTS 10 OUTP2 TRACE1 RATE 0 183 OUTP2 TRACE1 TRIGGER OUTP2 TRACE1 COMPLETE 1 OUTP2 TRACE1 92 87 92 87 92 87 92 87 92 87 92 87 92...

Страница 30: ...yntax OUTPut n TRACE m RATE wsp value MIN MAX DEF Description Set the trace buffer sampling rate Parameters value Set the desired sample rate in samples per second Hz MIN Set the minimum sample rate in samples per second Hz MAX Set the maximum sample rate in samples per second Hz DEF Set the default sample rate set at power on Response None Example OUTP1 TRACE1 RATE 500 Command OUTPut n TRACE m RA...

Страница 31: ...e in a clean and dry area Keep the unit out of direct sunlight Avoid high humidity or significant temperature fluctuations Avoid unnecessary shocks and vibrations If any liquids are spilled on or into the module power off the chassis immediately Remove the DopplerPXIe and allow to dry completely WARNING The use of controls adjustments and procedures other than those specified herein may result in ...

Страница 32: ...rdous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量 要求 Part Name 部件名称 Toxic or hazardous Substances and Elements 有毒有害物质和元素 Lead 铅 Pb Mercury 汞 Hg Cadmium 镉 Cd Hexavalent Chromium 六价铬 Cr VI Polybrominated biphenyls 多溴联苯 PBB Polybrominated diphenyl ethers 多溴二苯醚 P...

Страница 33: ...ification label as well as a description of your problem close at hand You may also be requested to provide software and module version numbers This information as well as technical support contact information can be found in the About window 9 2 Transportation Maintain a temperature range within specifications when transporting the unit Transportation damage can occur from improper handling The f...

Страница 34: ...glected or damaged by accident THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL COHERENT SOLUTIONS BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES 10 2 Liability Coherent Solutions shall not be liable for damages resulting from the u...

Страница 35: ...cover Support personnel will determine if the equipment requires service repair or calibration 2 If possible back up your data before sending the unit for repair 3 Pack the equipment in its original shipping material Be sure to supply a statement or report fully detailing the defect and the conditions under which it was observed 4 Return the equipment prepaid to Coherent Solutions Note A test setu...

Страница 36: ...V1 1 ...

Отзывы: