Option 4.4 - Connecting EV-Box charging station
Install a circuit breaker or earth leakage circuit breaker at the maximal
power available.
See p. 10.
Follow the installation instructions of the charging station. These
instructions can be found in the installation manual of the charging
station.
Place a suitable UTP (CAT5 or CAT6) of the EV-Box to Maxem. (To prevent electromagnetic
interference with the RS485 connection, it is recommended to use FTP CAT6 cable at
distance more than 25 m. Maximal distance is 50 m).
Crimp the supplied RJ10 4P4C connector on Maxem side on the data cable:
•
Connect wire 1 (orange-white) to Pin 1
•
Connect wire 2 (orange) to pin 2
•
Connect two other wires for pull relief
Connect the RJ10 4P4C connector to Maxem RS2 port.
Connect these two cores of the data cable to the quadrupole communication port of
EV-Box modem:
•
Connect one wire (orange-white) to Port A
•
Connect wire 2 (orange) to port B
•
The remaining ports do not have to be connected
A
A
167
184
55.50
SECTION A-A
Client:
Rev. nr:
1:1
Units:
1/2
CES-01 - Enclosure
MH
Vol. (mm³):
mm
Sheet:
Scale:
-
Cohere
Date:
Drawn:
File reference:
Drawing name:
-
Material:
17-02-2016
Maxem 4 Assembly
A3
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
<0,2x45° or R<0,2
Ra 0,8 um
Default length tolerances: DIN 7168
±20'
Default angle tol.:
Finish:
Default edges:
Roughness:
Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8
Dim.: 0-6 7-30 31-120 121-400 401-1000
RS2 port for charging station
Scheme EV-Box controller
Pin 1
Pin 2
Connect Maxem with the supplied network cable to the modem or router connected
to the Internet.
A
A
167
184
55.50
SECTION A-A
Client:
Rev. nr:
1:1
Units:
1/2
CES-01 - Enclosure
MH
Vol. (mm³):
mm
Sheet:
Scale:
-
Cohere
Date:
Drawn:
File reference:
Drawing name:
-
Material:
17-02-2016
Maxem 4 Assembly
A3
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
<0,2x45° or R<0,2
Ra 0,8 um
Default length tolerances: DIN 7168
±20'
Default angle tol.:
Finish:
Default edges:
Roughness:
Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8
Dim.: 0-6 7-30 31-120 121-400 401-1000
Ethernet port to
Internet Router
A
A
167
184
55.50
SECTION A-A
Client:
Rev. nr:
1:1
Units:
1/2
CES-01 - Enclosure
MH
Vol. (mm³):
mm
Sheet:
Scale:
-
Cohere
Date:
Drawn:
File reference:
Drawing name:
-
Material:
17-02-2016
Maxem 4 Assembly
A3
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
<0,2x45° or R<0,2
Ra 0,8 um
Default length tolerances: DIN 7168
±20'
Default angle tol.:
Finish:
Default edges:
Roughness:
Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8
Dim.: 0-6 7-30 31-120 121-400 401-1000
Connect Maxem with the included 230V feeding cable to a plug on the meter box.
Make sure this plug is connected to Phase 1 of the power supply. Maxem measures the
voltage through the power supply. It is therefore important to know to which phase the
power supply is connected.
Check that all components are connected to Maxem.
20
21
12V/DC
AB
GND
Tab above
A.
B.
C.
D.
E.
F.
A.
B.
C.
A
A
167
184
55.50
SECTION A-A
Client:
Rev. nr:
1:1
Units:
1/2
CES-01 - Enclosure
MH
Vol. (mm³):
mm
Sheet:
Scale:
-
Cohere
Date:
Drawn:
File reference:
Drawing name:
-
Material:
17-02-2016
Maxem 4 Assembly
A3
Stereo Design | Zamenhofstraat 150 - unit 336 | 1022AG | Amsterdam | Netherlands | T: +31 (0) 20 636 0671 | M: [email protected]
<0,2x45° or R<0,2
Ra 0,8 um
Default length tolerances: DIN 7168
±20'
Default angle tol.:
Finish:
Default edges:
Roughness:
Tol.: ±0,1 ±0,2 ±0,3 ±0,5 ±0,8
Dim.: 0-6 7-30 31-120 121-400 401-1000
RS2
05 - Connecting Maxem
Cores for pull
relief