In-Sight Strobe Light Adapter Installation & Reference
8
•
Trigger via the Discrete I/O
Connect your trigger circuit to IN+ and IN- terminals on the In-Sight processor (Discrete
I/O Lines 8 and 9 are on the processor) using the terminal block. Remember to set the
Discrete Input
Type
to
Acquisition Trigger
from the Discrete Input dialog (Figure 2-7).
Also, set the
Trigger
Parameter within the AcquireImage function’s property sheet to
External
Figure 2-7: Discrete Input Dialog