In-Sight® 1400 I/O Expansion Module Installation and Reference Manual
9
Figure 2-6: Discrete Output Settings
4.
In the bottom left of the Discrete Output Settings dialog, select CIO-1400 from the
Output Module list. The dialog will change to correspond to the available discrete
outputs on the 1400 I/O Expansion Module.
5.
Configure the discrete output line settings (Line Name, Type and Details), and click
OK to save the new settings to the sensor’s memory. See
for a basic
overview of the Discrete I/O Settings. The
In-Sight
®
Explorer Help
file (F1) contains
a more detailed explanation of these settings.
6.
Select OK to save the settings to the sensor’s memory.
Notes:
• The sensor can also be configured to recognize the 1400 I/O Expansion Module by
selecting Discrete Input Settings from the Sensor menu and following steps
.
• When an In-Sight Explorer .JOB file containing a WriteDiscrete function is loaded on
an In-Sight sensor to which the I/O Expansion Module has just been added, the Start
Bit and Number of Bits parameters in WriteDiscrete must be changed to reflect the
new configuration of the I/O lines.
Содержание In-Sight 1400
Страница 1: ...In Sight Vision for Industry In Sight 1400 I O Expansion Module Installation and Reference Manual...
Страница 2: ......
Страница 4: ...Copyright Trademarks Patents ii...
Страница 6: ...Regulations Conformity iv...
Страница 8: ...Precautions vi...
Страница 12: ...List of Figures x...
Страница 14: ...List of Tables xii...
Страница 26: ...Installation 12...
Страница 36: ...Specifications 22...
Страница 42: ...Appendix A Configuring Discrete Inputs 28...
Страница 57: ......
Страница 58: ...In Sight 1400 I O Expansion Module Installation and Reference Manual www cognex com P N 597 0104 01...