Indicator Lights

The CoaXPress status indicator lights directly behind the BNC connectors
(reference Page 4) follow specific color schemes detailed by CoaXPress standard
Version 1.1.

CoaXPress States

CoaXPress Indicator Light

No power

Off

System booting

Solid Orange

Connection detection in progress, PoCXP active

Fast flash alternate green / orange shown
for a minimum of 1s even if the connection
detected is faster

Device / Host incompatible, PoCXP active

Slow flash alternate red / green

PoCXP over-current (Host only)

Solid red

Device / Host connected, but no data being transferred

Solid green

Device / Host connected, waiting for event (e.g. trigger, exposure
pulse)

Slow pulse orange

Device / Host connected, data being transferred

Fast flash green

Error during data transfer (e.g. CRC error, single bit error detected) 500ms red pulse in case of multiple errors,

there shall be at least two green fast flash
pulses before the next error is indicated

System error (e.g. internal error)

Fast flash red

8

Содержание DSMax Frame Grabber

Страница 1: ...DSMax Frame Grabber Installation and Reference 2020March12 Revision 9 6 0 2...

Страница 2: ...substances or static electricity l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s authority to operate the equipment l Includ...

Страница 3: ...ing the CoaXPress protocol Two coaxial cables attach a DSMax sensor to the frame grabber with BNC connectors The DSMAX Frame Grabber has two general operating states Mode Connection to DSMAX Sensor He...

Страница 4: ...Layout 4...

Страница 5: ...ows OS Video Card 1 NVIDIA Quadro K620 2GB DP DL DVI I 1DP to SL DVI adapter Storage 1 2 TB 3 5 Serial ATA 7 200 RPM Hard Drive Storage 2 SHPM2280P2H 480GB SSD PCIe slots x4 Gen2 2 for dual frame grab...

Страница 6: ...ction 2 Turn off the PC and remove its cover 3 Select a free PCIe x4 Gen2 expansion slot 4 Remove the slot cover and store it for later use 5 Remove the hex nut and washer highlighted from the base of...

Страница 7: ...ly to the 6 pin Molex PCIe auxiliary power connector 9 Replace the cover of the PC 10 Connect the coaxial cables to the Frame Grabber using the BNC connectors I DSMax does not support single cable acq...

Страница 8: ...tion detected is faster Device Host incompatible PoCXP active Slow flash alternate red green PoCXP over current Host only Solid red Device Host connected but no data being transferred Solid green Devi...

Страница 9: ...Encoder PhA Floating input Use this when you need to use a single ended input Encoder PhA Weak pull up to 2 5V Encoder PhB Floating input Use this when you need to use a single ended input Encoder Ph...

Страница 10: ...PC supports the following BIOS settings they should be modified as follows l Change C States to off l Change Speedstep to off l Change PCI Performance Mode to on l Change PCI MMIO Space Size to Large...

Страница 11: ...nment for 24 hours l Use only Cognex supplied accessories with the DSMAX Sensor Head Contact your local Cognexsales representative for more information with any questions about compatible accessories...

Страница 12: ...representative l In case of any necessary servicing or repairing processes return the unit to the factory l Service is only to be handled by authorized factory trained technicians The DSMAX Frame Grab...

Страница 13: ......

Страница 14: ...Cognex Corporation All Rights Reserved Printed in the USA 14...

Отзывы: