background image

DataMan

®

8700 DX

Reference Manual

2020 June 24
Revision: 6.2.0.126

Содержание DataMan 8700 DX

Страница 1: ...DataMan 8700 DX Reference Manual 2020June24 Revision 6 2 0 126 ...

Страница 2: ...ny means electronic or mechanical for any purpose nor transferred to any other media or language without the written permission of Cognex Corporation Copyright 2020 Cognex Corporation All Rights Reserved Portions of the hardware and software provided by Cognex may be covered by one or more U S and foreign patents as well as pending U S and foreign patents listed on the Cognex web site at cognex co...

Страница 3: ...Man 8700DX Reader 12 Connection Options 13 Connecting Corded DataMan 8700DX 13 Troubleshooting an Ethernet Connection 13 Using Your Device Through USB 13 Changing Communication in DataMan 8700 Corded Reader 14 Reading Codes with the DataMan 8700 17 Industrial Protocols 17 Trigger Types 17 Field of View and Reading Distances 18 Cleaning and Maintenance 20 Cleaning the Reader Housing 20 Cleaning the...

Страница 4: ... a hazard that could cause death serious personal injury or electrical shock CAUTION This symbol indicates a hazard that could result in property damage Note This symbol indicates additional information about a subject Tip This symbol indicates suggestions and shortcuts that might not otherwise be apparent 4 Symbols ...

Страница 5: ... high voltage power sources to reduce the risk of damage or malfunction from the following causes over voltage line noise electrostatic discharge ESD power surges or other irregularities in the power supply l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user s authority to operate the equipment l Ensure that the cable bend radius...

Страница 6: ...nology and 2DMax algorithms to read the most challenging Direct Part Mark barcodes Tri Lucent Lighting provides flexible lighting control to create polarized bright field and diffuse lighting The DataMan 8700 readers are available with the following communication options l Ethernet with industrial protocols l USB l RS 232 DataMan 8700 Accessories Miscellaneous Accessories Accessory Name Accessory ...

Страница 7: ...cessory Number Accessory Image POE Adapter CPS AC POE1A xx1 Wall Mount Bracket DMA WALL 8700 Presentation Stand can be used with wall mount bracket DMA WALL 8700 DM STAND 00 1 xx can be US EN UK or JP 7 Getting Started ...

Страница 8: ...MC HH USBA 02 USB straight cable with type C connector 2 5 m DMC HH USBC 02 USB coiled cable with type A connector 2 5 m DMC HH USBA 02C USB cable with type C connector coiled 2 5 m DMC HH USBC 02C Ethernet coiled cable with RJ45 connector 5 m DMC HH ENET 05C1 Ethernet straight cable with RJ45 connector 2 5 m DMC HH ENET 02 Ethernet straight cable with RJ45 connector 5 m DMC HH ENET 05 Ethernet st...

Страница 9: ...an 8700 Reader 1 LED aimer 2 Trigger press and hold to read 3 Cable 4 360 ring light indicator 5 Lanyard hook 6 OLED display 7 Buttons for OLED input and configuration 8 Diffused light 9 Polarized light 10 Direct light 9 Getting Started ...

Страница 10: ...DataMan Setup Tool and click Refresh 3 Select your DataMan 8700 Series reader from the list and click Connect Setting Up the Reader To connect to the reader or base station on your computer 1 Install the DataMan Setup Tool on your computer 2 Select the connection type Ethernet RS 232 Serial or USB and connect the cables respectively 3 Turn on your device s DataMan 8700 DX Specifications Specificat...

Страница 11: ...PC JAN POSTNET PLANET Code GS1 IMB 2 D barcodes MaxiCode Aztec Code Data MatrixTM QR Code and microQR Code PDF 417 Power Supply Requirements Serial USB 5 5 V DC 6 0 W maximum LPS or NEC Class 2 power supply Ethernet PoE Class 2 power supply Inrush current peak In DC and USB mode 3 A maximum Maximum capacity 10 µF Maximum inrush 50 µC Ethernet 10 100 Base T FULL HALF DUPLEX IEEE 802 3 Protection IS...

Страница 12: ...ger Image Sensor 1 3 inch CMOS Image Sensor Properties 3 45 μm square pixels Image Resolution 1440 x 1080 pixels LED Wavelengths for DataMan 8700DX Reader The following table shows LED types and the related wavelengths LED λ nm RED 660 12 Setting Up Your DataMan 8700 ...

Страница 13: ...t menu or the Setup Tool Help menu This allows the reader to acquire a suitable IP address from a DHCP server on your subnet If the reader still does not appear you can use the Add Device option in the DataMan Setup Tool If you know the IP address of the reader use the Add Network Device option under Repair Support This method allows the DataMan 8700 reader to appear in the list of Network devices...

Страница 14: ...g USB Ethernet and RS 232 slide in communication type conversion kits Follow the steps to change the communication conversion kit 1 Remove the four screws located on the end cap assembly at the base of the reader using a Hex 2 0 mm screwdriver Note Save the screws for later use 2 Pull out the end cap assembly with the internal communication slide in 3 Separate the internal slide in from the end ca...

Страница 15: ...4 Line up the new communication slide in with the rails on the internal sides of the reader 5 Insert Internal communication slide in 6 Replace the end cap assembly 15 Connection Options ...

Страница 16: ...7 Insert the screws into the end cap assembly using a Hex 2 0 mm screwdriver Note Use 0 6 Nm 5 31 in lb torque on the screws and tighten in the sequence shown in the image 16 Connection Options ...

Страница 17: ...ration codes see the Reader Configuration Codes Manual available through the Windows Start menu the Setup Tool Help menu or the Cognex Documentation Portal l Send the appropriate DMCC see the DataMan Control Commands Documentation available through the Windows Start menu or the Setup Tool Help menu For more information on using the industrial protocols see the Industrial Protocols Manual available...

Страница 18: ...f View and Reading Distances The following map shows the range of reading distances available for different code sizes and focus positions Working Distance Horizontal Values Vertical Values Z1 40 mm 1 57 in X1 63 mm 2 5 in Y1 47 mm 1 8 in Z2 140 mm 5 5 in X2 126 mm 5 in Y2 95 mm 3 7 in Z3 300 mm 11 8 in X3 288 mm 11 3 in Y3 171 mm 6 7 in Distances in mm 1D min code Distances in mm 2D min code 18 5...

Страница 19: ...Note The calibration distance is 143 0 mm from the nose of the lens and the calibration tolerance is 5 mm 19 Reading Codes with the DataMan 8700 ...

Страница 20: ...th harsh or corrosive solvents including lye methyl ethyl ketone MEK or gasoline Cleaning the Reader Lens Cover To remove dust from the lens cover use a pressurized air duster The air must be free of oil moisture or other contaminants that could remain on the lens cover To clean the plastic window of the lens cover use a small amount of isopropyl alcohol on a cleaning cloth Do not scratch the plas...

Страница 21: ...C Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area...

Страница 22: ... management methods for controlling pollution by electronic information products Hazardous Substances 有害物质 Part Name 部件名称 Lead Pb 铅 Mercury Hg 汞 Cadmium Cd 镉 Hexavalent Chromium Cr VI 六价铬 Polybrominated biphenyls PBB 多溴联苯 Polybrominated diphenyl ethers PBDE 多溴二苯醚 Regulatory Model R00083 X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 这个标签是根据SJ T 11364 的规定准备的 O In...

Страница 23: ...Copyright 2020 Cognex Corporation All Rights Reserved ...

Отзывы: