![Cognex DataMan 60 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/cognex/dataman-60-series/dataman-60-series_quick-reference-manual_2634690014.webp)
Digital Input Lines
Inputs are not galvanic isolated but need to be referenced to ground.
Input-0/Input-1
ESD Protection
Constant 2mA
current sink
Input-Internal-1/
Input-Internal-2
(Internal Signals)
+V
dd
DM60 sinking
OUT
PLC
COM
+ -
External Wiring Examples: Digital Input
Lines
26 DataMan 60 Quick Reference Guide
DataMan 60 Quick Reference Guide 27
Flying Leads Cable
PIN
Color
Signal
2
Green
TxD
3
Green/Black
RxD
4
Red
GND
5
Brown/White
DC+ (system power,
5-24 VDC)
6
Blue
RTS
7
Blue/White
Output-0
8
White
Input-0
9
White/Black
Input-1
10
Light Blue
CTS
11
Light Blue/Black
Output-1
12
Light Blue/Yellow Output-Common
13
Light Blue/Green Output-Strobe
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
This is a female
connector/socket.
You can connect a cable with flying leads to the cable that is attached to the
device. The following table shows the pinout and color description of the flying
leads.
Содержание DataMan 60 Series