Connecting the Power and I/O Breakout Cable
CAUTION
:
To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note
:
l
Perform wiring or adjustments to I/O devices when the reader is not
receiving power.
l
You can clip unused wires short or use a tie made of non-conductive
material to tie them back. Keep bare wires separated from the
+24VDC wire.
1.
Verify that the 24VDC power supply is unplugged and not receiving power.
2.
Attach the Power and I/O Breakout cable's +24VDC and Ground wires to
the corresponding terminals on the power supply. For more information,
see
CAUTION
:
Never connect voltages other than 24VDC. Always
observe the polarity shown.
3.
Attach the Power and I/O Breakout Cable's M12 connector to the reader's
24 VDC connector.
4.
Restore power to the 24VDC power supply and turn it on if necessary.
Using your device through USB
You can utilize the DataMan 280's USB connector in three different ways:
31