4. Attach the 16 mm lens mount.
5. Fasten the two M2x5mm Phillips head screws to 0.06 Nm using a torque wrench.
6. In the case of a manual focus lens, press the 16 mm lens cap onto the lens. The lens has 12 cutouts so it can be
locked in steps of 30 degrees.
In the case of a liquid lens, mount the liquid lens cap onto the 16 mm lens. (See
Installing a Liquid Lens
on
page 27
.)
7. Attach the illumination board.
Note
: Take care to attach the illumination with the right orientation.
22
Setting Up Your DataMan 260
Содержание DataMan 260
Страница 1: ...DataMan 260 Reference Manual 08 24 2016 Version 5 6 3...
Страница 19: ...19 Getting Started...
Страница 32: ...DM262 6 2 mm Lens 32 Setting Up Your DataMan 260...
Страница 46: ...Signal PoE Ethernet Model 46 Connections Optics and Lighting...
Страница 49: ...49 Connections Optics and Lighting...
Страница 56: ......