22  DataMan 100 Verifier Quick Reference

DataMan 100 Verifier Quick Reference  23

Formatting Output Data

Use the 

Data Formatting

 task pane of the DataMan Setup Tool to construct 

a customized output string each time you read and verify a symbol. This 

allows the verifier to return Code Quality results when connected to a third-

party application instead of the DataMan Setup Tool. 

In addition to standard formatting, the DataMan Setup Tool supports the 

use of Perl-Style Regular Expression features in Advanced mode. 

Data Logging

Use the 

Data Logging

 task pane to generate a Code Quality Report for 

each symbol that you read and verify. Be aware that data logging works 

only when the reader is connected to the DataMan Setup Tool. 

In addition, you can enable the 

Prefix filename with

 option to give 

each Code Quality Report a set prefix. 

Select 

1. 

View->Advanced

 if the DataMan Setup Tool is not in 

Advanced mode.

Select the 

2. 

Data Logging

 task pane under 

System Settings

. 

Enable the 

3. 

Report Storage

 option and use the 

Save in

 option, as 

shown in the following example, to configure a directory location to 

save each report along with an image of the verified symbol: 

Содержание DataMan 100

Страница 1: ...COGNEX DataMan 100 Verifier Quick Reference ...

Страница 2: ...onfiguration Codes Page 22 4 Calibration and Verification Calibrate the DataMan 100 Perform Code Quality Verification Code Quality Results Page 16 3 Preparing the Reader Install the DataMan 100 Software Prepare to use Verifier Light Focus the Lens Connect the Red Lens Cover Page 10 2 Hardware Installation Kit Contents Install the SHD Lens Mount the Reader Wiring Page 2 1 ...

Страница 3: ...DULE OK OUT 7 OUT 6 OUT 5 OUT 4 OUT 3 OUT 2 HS OUT 1 HS OUT 0 OUT COMMON TRIGGER TRIGGER RS232 OUT 2 DataMan 100 Verifier Quick Reference DataMan 100 Verifier Quick Reference 3 DataMan 100 Verifier Kit Contents DataMan 100 Calibration card ESD front cover The DM100 100V 00 kit contains only these components while the DM100 100V 01 kit contains all the components on this page Light assembly 16 mm l...

Страница 4: ...s 1 2 Installing the SHD kit causes the factory lens calibration to be lost If you wish to remove the SHD kit later and re use the original DataMan 100 lens contact Cognex for assistance 3 4 Do not leave the DataMan sensor 100 lens mount open to the environment or you risk contaminating the DataMan 100 image sensor with dirt and dust ...

Страница 5: ...6 DataMan 100 Verifier Quick Reference DataMan 100 Verifier Quick Reference 7 5 Mount the Reader 1 Install the SHD Lens 6 ...

Страница 6: ...MODULE OK OUT 7 OUT 6 OUT 5 OUT 4 OUT 3 OUT 2 HS OUT 1 HS OUT 0 OUT COMMON TRIGGER TRIGGER RS232 OUT 24 VDC 8 DataMan 100 Verifier Quick Reference DataMan 100 Verifier Quick Reference 9 The lighting attachment offers five mounting positions Wiring 2 Mount the Reader Cable cannot exceed 5 meters in length ...

Страница 7: ... NET 1 1 SP1 installed automatically Insert the installation CD and follow the on screen prompts 1 Launch the Setup tool 2 Click 3 Scan Ports The Port field must show DM100 to establish a conection Click 4 Connect Prepare to use Verifier Light 1 2 You must install the DataMan software regardless of which DataMan kit you use Your PC must meet the following minimum requirements ...

Страница 8: ...12 DataMan 100 Verifier Quick Reference DataMan 100 Verifier Quick Reference 13 1 2 3 Focus the Lens Adjust the lens focus while observing the image display in the Setup tool 4 ...

Страница 9: ...rence DataMan 100 Verifier Quick Reference 15 Connect the Red Lens Cover 1 2 3 Adjust lens so that a slot aligns with the locking tab in the cover Tighten screws in the order shown Maximum torque for the cover screws is 9 N cm 0 79 pound inch 4 ...

Страница 10: ...DataMan 100 1 2 3 Click Check 4 Align the calibration symbol from the calibration card under the DataMan reader 5 Press and hold the trigger button 6 Use the calibration graphics to align the calibration symbol with the DM100 You have to calibrate the DataMan 100 regardless of which kit you use ...

Страница 11: ...rm Direct Part Mark verification your reader must be calibrated as described in the previous section To read symbols and view verification results perform the following steps Start the DataMan Setup tool and connect to your reader 1 Enable the 2 Turn Code Quality On icon in the tool bar Select the 4 Results Display task pane Place the symbol under the reader and press the trigger The symbol 5 must...

Страница 12: ...ithin the green target rectangle and turns green Code Quality Results The Results Display task pane presents the results of the verification on the right hand side Overall verification result Pass Fail Individual AIM DPM metrics and grades Process control metrics if enabled For more information on interpreting the verification results select View Q A Help The Results Display task pane can toggle b...

Страница 13: ...xpression features in Advanced mode Data Logging Use the Data Logging task pane to generate a Code Quality Report for each symbol that you read and verify Be aware that data logging works only when the reader is connected to the DataMan Setup Tool In addition you can enable the Prefix filename with option to give each Code Quality Report a set prefix Select 1 View Advanced if the DataMan Setup Too...

Страница 14: ...A saved configuration can be opened later and uploaded to any reader allowing multiple readers to use the same configuration settings Be aware however that each reader must be calibrated individually Code Quality Configuration Codes Use the following Code Quality configuration symbols to quickly turn Code Quality on and off without connecting the reader to the DataMan Setup Tool Additional Code Qu...

Страница 15: ...26 DataMan 100 Verifier Quick Reference DataMan 100 Verifier Quick Reference 27 ...

Страница 16: ...out the written permission of Cognex Corporation The hardware and portions of the software described in this document may be covered by one or more of the U S patents listed on the Cognex web site http www cognex com patents asp Other U S and foreign patents are pending Cognex the Cognex logo and DataMan are trademarks or registered trademarks of Cognex Corporation ...

Отзывы: