Precautions
Observe these precautions when installing Checker to reduce the
risk of injury or equipment damage:
•
Do not attempt to adjust Checker’s focus when moving parts
and/or equipment are present.
•
Use a listed power supply with an output rated 24VDC, at
least150mA, and marked Class 2, Limited Power Source
(LPS). Any other voltage creates a risk of fire or shock and can
damage Checker.
•
Do not install Checker in locations that expose it to
environmental hazards such as excessive heat, humidity,
impact, vibration, corrosive substances, flammable
substances, or static electricity.
•
To reduce the risk of damage or malfunction, route all cables
and wires away from high-voltage power sources.
•
Do not attempt to modify Checker. Modifications will void the
warranty.
Getting Help
On-line support is available at
support.cognex.com
, or you may
contact Cognex directly:
Additional Information
NOTE:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Copyright © 2005 Cognex Corporation All Rights Reserved
This document may not be copied in whole or in part, nor transferred to any other media or
language, without the written permission of Cognex Corporation.
The hardware and portions of the software described in this document may be covered by
one or more of the U.S. patents listed on the Cognex web site
http://www.cognex.com/patents.asp. Other U.S. and foreign patents are pending.
Checker, CheckMate, Cognex, and the Cognex logo are trademarks, or registered
trademarks, of Cognex Corporation. Microsoft, Windows, and the Windows logo are
trademarks, or registered trademarks of Microsoft Corporation in the United States and/or
other countries.
590-6590 Revision 1.3
Region
Telephone
Direct E-Mail
North
America
+1-508-650-6300
Japan
+81-3-5977-5400
Europe
+33 1 47771550
Cable (power and I/O)
24AWG, 12’, pigtail
24V power fuse
Output fuse
500 milliamp, 60V rated resettable fuse that will
recover after an overload is removed. Protects
against over voltage and reverse wiring.
200 milliamp, 30v rated resettable fuse that will
recover after an overload is removed. Protects
each output from over current.
Weight
8.47 oz (240 g)
Operating temperature
Storage temperature
Operating humidity
Protection
Maximum altitude
Shock
Vibration
32° to 122°F (0° to 50°C)
-22° to 176°F (-30° to 80°C)
0% - 90% non-condensing
IP67
2000 meters
80Gs for 5ms on each axis (per IEC 68-2-2)
10Gs (10-500Hz) at 100 M/sec
2
/ 15mm for 2
hours in each axis (per IEC 68-2-6)
7
48
6
25
3
1
9
13
6
24
8
57
1
2
91
0
1
3
1
1
14
18
15
16
17
21
19
20
22
Use this ruler to meas
ur
e the field of view
.
Place the ruler the same distance fr
om
Checker as your par
t will be.
Inc
h
es
mm
Содержание Checker 101
Страница 1: ...Quick Reference...