Figure 32 shows an example using the contact closure output wiring configuration.
Output is taken directly from and Strobe–. This output functions as a contact
closure switch. Ensure that current (125 mA) and voltage (24 V) limits are not exceeded.
Figure 32. Contact closure wiring of strobe
Opto-isolator
Strobe –
330
Ω
Camera
Output
Strobe