MVS-8100D Hardware Description
2
30
Cognex MVS-8100D and CDC Cameras Hardware Manual
Indicator LEDs
There are four LEDs on the faceplate of the MVS-8100D. Looking directly at the
faceplate, the LEDs are one red and three green LEDs, left to right, as shown in
Figure 11.
Figure 11. Indicator LEDs on faceplate
The LEDs indicate the conditions shown in Table 14.
Camera Connector and Cables
The MVS-8100D receives streams of digital video signals from one or more Cognex CDC
series cameras through the 26-pin camera connector. You connect a camera cable or
breakout cable from Table 15 to the camera connector. Note that Cognex CDC series
cameras use a micro DB-9 connector.
LED
Condition
Red
In normal operation, this LED is off. When first powered on, the
MVS-8100D loads instructions stored in flash memory into an
onboard chip. This red LED stays on while the load is in progress,
which should take less than one second. If this LED stays on after
power-up, turn off the PC and restart it. If the LED remains on,
contact Cognex Technical Support.
Left green
When the MVS-8100D’s device driver is loaded and enabled, this
LED indicates a successful link with a CDC series camera over the
CogLink bus, for camera channel two (on three camera models).
Middle green
Same, for camera channel one (on two or three camera models).
Right green
Same, for camera channel zero (on all models).
Table 14. Faceplate LEDs and conditions indicated
camera channels
21 0
Load
failure
Link indicators for