Product Service
Cognex Corporation makes the following recommendations for cleaning the external optical surfaces
of a DSMax sensor:
l
Unplug the DSMAX Sensor Head so the laser cannot be powered on
l
Use lint-free tissue or an optical-grade cotton swab (“Q-tip”)
l
Use reagent-grade acetone and isopropyl alcohol
l
Use minimal pressure
l
Dispose of tissue and/or swab after each swipe to prevent lint deposition
l
Swipe in a single, even stroke across optical surfaces
l
Rotate the tissue or swab during cleaning so dirt is not dragged across the surface
If the DSMAX Sensor Head is soiled such that full liquid immersion is required, fasten TNC caps to I/O connectors
and rinse the unit with appropriate cleaning fluid. Failure to fasten TNC caps before immersion will result in
IRREPARABLE DAMAGE to the DSMAX Sensor Head.
l
The DSMAX Sensor Head cannot be serviced by the customer. Please bring any performance issues to
the attention of your local Cognexrepresentative.
l
In case of any necessary servicing or repairing processes, return the unit to the factory.
l
Service is only to be handled by authorized factory-trained technicians. The DSMAX Sensor Head does
not contain parts that are user-serviceable.
l
Under no circumstances should you operate the DSMAX Sensor Head if it is defective or the seal
damaged. CognexCorporation cannot be held responsible for any harm caused by operating a faulty unit.