FAU LT F I N D I N G G U I D E
FAULT
POSSIBLE CAUSE
ACTION
FATAL I
2
C ERROR
Displayed
(a)
Electrical noise
(b)
MPU Board fault
(c)
Software error
(a)
Check motors
(b)
Replace MPU Board
(c)
Reset power
Keypad does not bleep
a)
Keypad damaged
(b)
Keypad disconnected
(c)
MPU Board fault
(a)
Replace keypad
(b)
Reconnect
(c)
Replace MPU Board
Drinks cold
(a)
Heater fuse blown
(b)
Thermal cut-out tripped
(c)
Desired
temperature
incorrectly set
(d)
Excessive
scaling
in
heater tank
(e)
Solid state relay fault
(f)
Temperature probe wet
a)
Check and replace
(b)
Reset trip
(c)
Check
desired
temperature setting
(d)
Check tank and descale
if necessary
(e)
Check relay
(f)
Dry probe and check
No motor operation
(a)
Jammed motor
(b)
Power Supply failure
safety trip
(a)
Check motor operation
(b)
Reset power
Machine inoperable;
no display
(a)
Power Supply failure
(a)
Replace Power Supply
Board
Heater tank
not filling
(a)
Low water pressure
(b)
Inlet valve fault
(c)
MPU Board fault
(a)
Check water pressure
(b)
Check inlet valve
(c)
Replace MPU Board
Heater tank
boiling over
(a)
Incorrect
desired
temperature setting
(b)
Temperature probe fault
(c)
MPU Board fault
(d)
Short on solid state
(a)
Reset
desired
temperature setting
(b)
Replace probe
(c)
Replace MPU board
(d)
Replace relay
Содержание VITRO S2 Series
Страница 1: ...VITRO S2 3 RANGE TECHNICAL MANUAL 81038540 Revision 1 ...
Страница 5: ...5 28 02 2017 Revision 1 VITRO S2 3 This page is intentionally blank ...
Страница 7: ...7 28 02 2017 Revision 1 VITRO S2 3 ...
Страница 38: ...VITRO S2 3 Revision 1 28 02 2017 38 TIMEOUT cashless device such as a card reader ...
Страница 47: ...47 28 02 2017 Revision 1 VITRO S2 3 ...
Страница 62: ...VITRO S2 3 Revision 1 28 02 2017 62 Section 4 Schematic and Exploded Parts Diagram ...
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ......
Страница 71: ......