Electrical connection
230 V/50 Hz/ 2,5 A
Water connection
3,0 m Tube with 3/8" internal thread (minimum 2,5bar
water pressure.)
Compressor
Elektrolux GL 80
Cooling gas
HFC-134 A Amount to fill 210 gram
Cooling capacity
294 W
Cooling throughput
40 litres per hour
Front light
24 W lamp
Front sign size
265 x 481 mm(16 mm must be transparent, Applies on the
bottom part of the sign.
Dispenser measurement
Height 750mm
With 250mm
Depth 550mm
Weight
34 Kg
Note 1.
The thermostat is factory adjusted and improper adjustment
may cause the cooling system to freeze causing damage or
water leakage in the dispenser.
Note 3.
It is strongly recommended to use some sort of water isolator in
the water line in case of an emergency leakage.
Note 4.
Maximum ambient temperature in the room where the dispenser
is located should not exceed more then 25 C.
Note 5.
If the dispenser has frozen, check water tubs and connections
inside the dispenser before running the dispenser again.
17
Technical Data
Page 17
Specifications
Operation Notes
Notes
Cooling system
Dry block with stainless-steel pipes inside.
Note 2.
Cooling system is factory set to 3-4 degree. Control thermostat
knob is adjustable for 3-8 degree range .
Note 6.
Differential temperature between on/off 3°C. i.e. compressor
off at 3°C then at 6°C compressor will start the cooling cycle
(this value could be affected if somebody changed the
setting of the thermostat control knob)