30.
10. Possible solutions.
Fault
Possible Solution
A. Switch does not lit.
1.
Check plug connection to wall socket.
2.
Check fuse in plug.
3.
Check if hot plate becomes warm, if so
replace switch.
B. Hot plate does not become
1.
Check connection to element.
warm although switch is lit.
2.
If element defective, replace.
C. Brewer excess steam.
1.
Machine may require descaling.
2.
Spray nozzel may need unblocking.
3.
Hose may be bent?
4.
Inlet to boiler may be blocked. Descale
machine - if boiler still defective - replace.
D. Machine will not brew.
1.
Check overheating protection.
2.
Check microswicth.
3.
Check float.
4.
Check connection to boiler.
5.
Boiler unit may need replacing.
F. The machine does not take in
1.
Make sure water-inlet is not closed.
water.
2.
Make sure the tube is not bent.
3.
Check solenoid.
4.
Check that the lamp on membran switch is
blinking.
G. The machines does not stop
1.
Dirt in the solenoid.
taking in water.
H. The machine is giving wrong
1.
Check watertap.
amount of water.
2.
Bent tube.
3.
Dirt in solenoid.
4.
Membran switch wrongly adjusted.
Adjust according to
installation manual page 24.
5.
Defect floatregulator in solenoid, change
solenoid.