background image

all  other  remote  CO  alarm  in  the  wireless  communication  rang  also  into 
silence status for 5 minutes.
Note: The alarm signal will re-energized within 5 minutes from the time the 
TEST&SILENCE button is operated if the concentration of CO surrounding the 
alarm remains at 45ppm or greater.
Human alarm sounds: If the unit come into the status of CO alarm warning, 
the unit will start in a lower volume (<80dB) for around 10 seconds, then 
issuing a normal volume (>85dB). It will avoid people to be scared suddenly 
by a very loud alarm sound.
Test the unit: To test the unit, press and hold TEST&SILENCE button about 0.2 
seconds then release to enable TEST&SILENCE button, you should hear alarm 
sound patterns and with a corresponding ALARM indicator (red LED) flash.
The  test  alarm  sound  pattern  includes:  4  short  beeps  (normal  volume), 
5seconds pause.
If other unit have been in the same network, also ring alarm sound and with 
a corresponding ALARM indicator (green LED) flash.
NOTE: 

• After the TEST&SILENCE button is enabled, the alarm sounds and the red 
alarm light flashes. This does not indicate that CO is present.
•  Test  the  unit  weekly!  If  at  any  time  your  unit  does  not  perform  as 
described, replace it immediately.

4. WIRELESS INSTRUCTIONS

Wireless  internet  alarm  instruction:  The  CO  supports  to  be 
interconnect with . If you purchase more than one of the types of 
products, please put them into the same network according to the following 
steps.
Networking  steps  without  host:  1)  Arbitrarily  select  a  product  as  master, 
connecting  the  battery.  In  2  seconds,  press  the  button  three  times  in  the 
warm-up  state  or  the  normal  standby  state,  this  product  into  the  host 
network state, while the red light will be lit about 10s. If you want to exit the 
network state, press the button.
2) Choose other products as a slave, connecting the battery. In 2 seconds, 
press the button three times in the warm-up state or the normal standby 
state, this product will be automatically with the host network. If the network 
is successful, the red light will flash many times, while the master and the 
slave has a sound. The master will extend the network time about 10 s.
3) According to step two, networking other products.
4) After all product networking, arbitrarily select a product, press the test 
button, this product is issued to test alarm sound, other products will ring one 
by one in 8 seconds.        
CAUTION:  Marked  as  the  master  of  the  product,  remember  it,  if  you 
purchasing a new CO, you must use this product as a master for 
networking.
Networking steps MDAHWF: This product can access the smart home host, if 
you purchasing a host, according to the following steps to access the host 
network. 
1)  Make  sure  the  host  into  networking  status  (see  instructions  of  the 
MDAHWF). 
2) Choose a product, connecting the battery. In 2 seconds, press the button 
three times in the warm-up state or the normal standby state, this product 
will be automatically with the host network. If the network is successful, the 
red light will flash three times, the product has a sound.
Clear network status: After networking wireless functions begin to work, if 
you want to exit the wireless function, follow this steps. 
1) Remove the battery.
2) Press the button and don't let go. And then connecting the battery, the red 
led will on 5 seconds, 5 seconds later, when the red light is off, then release 
the button.

 

 

3) When the button is released, the red light is lit for 3 seconds. In these 3 
seconds, press the button, you can clear the network. After the success of the 
product will be a ring.

5. WHAT TO DO IF THE ALARM SOUNDS

WARNING! Action of this device indicates the presence of dangerous levels of 
CO! CO can be fatal! If the alarm sounds:
If a carbon monoxide apparatus initiates an alarm signal it is recommended 
that the following actions are taken in the order given:
1) Keep calm and open all doors and windows to increase the rate of 
ventilation, but see also item a) below. Stop using all fuel-burning appliance 
and  ensure,  if  possible,  that  they  are  turned  off,  e.g.  for  gas  appliances, 
isolate the emergency control valve.
2) If the alarm continues to be activated, then evacuate the premises. Leave 
the doors and windows open, and only re-enter the building when the alarm 
has stopped. In multi-occupancy and multi-storey premises, ensure that all 
the occupants are alerted to the risk.
3)  Get  medical  help  for  anyone  suffering  the  effects  of  carbon  monoxide 
poisoning and advise that carbon monoxide inhalation is suspected.
4) Telephone the appropriate appliance servicing and/or maintenance agency 
or, when necessary, the relevant fuel supplier on their emergency number or 
the  national  Gas  Emergency  Service  Provider,  if  appropriate,  so  that  the 
source of carbon monoxide emissions can be identified and corrected. Unless 
the reason for the alarm is obviously spurious, do not use the fuel-burning 
appliance  again,  until  they  have  been  checked  and  cleared  for  use  by  a 
competent person according to national regulations. 

6. BATTERY INSTALLATION/REPLACEMENT

Twice chirps with corresponding FAULT indicator (yellow LED) flashing twice 
every 30 seconds indicates that the battery is low battery, you must to replace 
the battery with battery specified, please see “8. TECHNICAL INFORMATION”
To install or replace the battery in unit, please perform the following steps:
1) Take down the unit from screw heads of the wall.
2) Open battery compartment.
3) Remove the old battery, and replaced by new battery.
4) Close battery compartment.
5) Hook the alarm body over the screw heads onto keyholes in back of the 
unit.
6) Test alarm using the TEST&SILENCE button, if the testing alarm is ok, means 
the product can work normally.
WARNING! Use only the battery specified. Use of different battery may have 
a detrimental effect on the CO alarm. A good safety measure is to replace the 
battery at least once a year.
NOTE:  Re  install  immediately  after  cleaning  and  then  test  unit  using  the 
TEST&SILENCE button!

7. GENERAL MAINTENANCE

To  keep  your  CO  alarm  in  good  working  order,  please  follow  these  simple 
steps:
1)  Verify  the  unit's  alarm  sound  and  indicators  operation  by  enable  the 
TEST&SILENCE button once a week.
2) Remove the unit from the wall and clean the alarm cover and vents with a 
soft brush attachment once a month to remove dust and dirt.
3) Never use detergents or other solvents to clean the unit.
4)  Avoid  spraying  air  fresheners,  hair  spray  or  other  aerosols  near  the  CO 
alarm.
5) Do not paint the unit. Paint will seal the vents and interfere with the 
sensor's ability to detect CO. Never attempt to disassemble the unit or clean 
inside. This action will void your warranty.

FABRICANTE DE PRODUCTOS CONTRA INCENDIOS - FIRE PROTECTION MANUFACTURER

Ctra. de Molins de Rei a Rubí, Km. 8,4 - 08191 RUBÍ (Barcelona) SPAIN.

Tlf.: +34 935 862 690 - Fax:+34  936 999 261 - [email protected] - www.cofem.com

1973