Error messages
If a malfunction occurs,
ReLite Led Kit
has a self-diagnostic system that will show the error message on the
display. The following table will explain in detail the most common errors. If, despite of suggested intervention,
the problem persists, call the
Coemar
Service Center.
9.7
Special functions of the fixture
Storing the DMX signal
To use the fixture without an active DMX console it is possible to store the DMX settings in two ways:
• Through the
TEST
menu
;
• Disconnecting the DMX signal when the fixture is on. When the signal is unconnected the fixtures stores
the signal;
Automatic fan standby
To decrease the noise and the power consumption the cooling fan turns off after 10 minutes of fixture inactivity.
Error code
Description
noal
[No Alarm]
No alarm
The projector self-diagnostic routine didn’t find any issue.
DTER
[Data Error]
Data error
Initial data loading has failed the projector loaded the default data settings:
restart the fixture again, and if the error persists contact the
Coemar
as-
sistance center.
ADER
[Address Error]
Address error
The projector does not receive all channels of DMX needs to function
properly. Check the DMX address indicated on the display and the num-
ber of channels generated by the mixer control. We recall in this connec-
tion that some controllers do not generate all the 512 channels.
LEd
[LED Error]
LED error
Auto diagnostic routine found that the LED module may damaged, con-
tact Coemar assistance for the module replacement.
IMPORTANT:
To ensure the sensor is giving correct readings, set the
LED to the maximum light output level.