1.1. Packaging

Open the packaging and ensure that no part of the equipment has suffered damage in transit. In case of damage to the equipment,
contact your carrier immediately by telephone or fax, following this with formal notification in writing.

Packing list

Ensure the packaging contains:

1 Pin Lite LED
1 Instruction manual

1.2. Transportation

The 

Pin Lite LED

should be transported in either its original packaging or in an appropriate flight case.

2.1. Important safety information

Fire prevention:

1.

Never locate the fixture on a flammable surface.

2.

Minimum distance from flammable materials: 0.5 m.

3.

Minimum distance from the closest illuminable surface: 0,5 m.

4.

Replace any blown or damaged fuses only with those of identical values. Refer to the schematic diagram if there is any doubt.

5.

Connect the projector to mains power via a thermal magnetic circuit breaker.

Prevention against electric shock:

1.

High voltage is present in the internal of the unit. Isolate the projector from mains supply prior to performing any function which
involves touching the internal of the unit.

2.

For mains connection, adhere strictly to the guidelines outlined in this manual.

3.

The level of technology inherent in the 

Pin Lite LED

requires the use of specialised personnel for all service applications; refer all work

to your authorised 

Coemar

service centre.

4.

A good earth connection is essential for proper functioning of the projector. Never operate the unit without proper earth connection.

5.

The mains cable should not come into contact with other cabling.

6.

Never handle the unit with wet hands or in a damp environment.

Safety:

1.

The projector should always be installed with bolts, clamps, and other fixings which are suitably rated to support the weight of the unit.

2.

Always use a secondary safety chain of a suitable rating to sustain the weight of the unit in case of the failure of the primary fixing point.

3.

Never install the fixture in an enclosed area lacking sufficient air flow; the ambient temperature should not exceed 35°C.

4.

The external surface of the unit, at various points, may exceed 80°C. Never handle the unit until at least 10 minutes have elapsed
since the unit was turned off..

Protection rating of the body against liquids and solids:

1.

The standard version of the fixture is classified ordinary apparatus; its protection grade against penetration by external agents,solid or
liquid, is 

IP 20

2. 

The IP version of the projector has an 

IP 65

protection rating; this indicates that it is protected against dust and significant showers

of water. This protection rating allows the fixture to be installed in an exposed location in inclement weather.

2.2. Warranty conditions

1.

The fixture is guaranteed for a period of 12 months against manufacturing faults and faulty materials.

2.

Faults due to incorrect operation or operation in an inappropriate manner are not covered by the warranty.

3.

The warranty is immediately void if the fixture has been operated or serviced by unqualified or unauthorised personnel.

4.

The warranty does not include fixture replacement.

5.

The model and serial numbers must be supplied for any warranty claims or advice from our authorised service personnel.

2.3. Certification

1.

The fixture satisfies the essential requirements of the directive EMC 89/336/EEC, 93/68/EEC, BT73/23/EEC.

2.

The fixture is in accordance with the standard EN 50419 (RoHS) and satisfies the requirements of the directive 2002/96/EC (WEEE).

2. General information

1. Packaging and transportation

English

4

Содержание PIN LITE LED

Страница 1: ......

Страница 2: ...ed above the relative service information of the model and the retailer from whom you purchased your Pin Lite LED this information will assist us in providing spare parts repairs or in answering any t...

Страница 3: ...Operating voltage and frequency 10 5 2 Mains connection 10 6 DMX signal functions Pag 11 6 1 Connecting DMX signal 11 6 2 Powering up 11 6 3 DMX addressing 12 6 4 DMX functions 12 7 Test function Pag...

Страница 4: ...e centre 4 A good earth connection is essential for proper functioning of the projector Never operate the unit without proper earth connection 5 The mains cable should not come into contact with other...

Страница 5: ...lbs IP Rating IP20 standard version IP65 IP version 3 2 Dimensions 3 3 Projector components The principal components of the Pin Lite LED are shown in the diagram below Descrizione dei componenti 1 IP...

Страница 6: ...e from a lighting truss or similar we recommend the use of appropriate clamps B affixed to the yoke in the hole A provided as shown in the following diagram Never install the fixture in a position in...

Страница 7: ...metal chain both suitably rated for the purpose 4 3 Adjusting beam direction The Pin Lite LED can be tilted to adjust the beam output To perform this adjustment follow the instructions set out below 1...

Страница 8: ...a group of lenses for a larger projection angle a flood reflector and several filters that can be fitted either internally or externally to the unit The standard optical group fitted on Pin Lite LED i...

Страница 9: ...8 1 as shown on following drawing The following table details the range of beam angle and diffusion filters available for the Pin Lite LED Optical group Beam angle 1 2 peak angle Narrow Lenses standar...

Страница 10: ...emperature 25 60 Connection to mains power for connection purposes ensure you plug is of a suitable rating 230 240V 0 2 amps constant current 208V 0 25 amps constant current 100 115V 0 5 amps constant...

Страница 11: ...n 2 data pin 3 data Should your DMX 512 controller output signal via a cannon XLR5 5 pin pins 4 and 5 should remain unconnected 6 2 Powering up After having followed the preceding steps turn on mains...

Страница 12: ...ionalcontrolofthepercentageofbluecolourfrom0to100 0 255 0 100 step noeffect 0 9 0 4 proportional variable speed strobing effect from slow to fast 10 57 4 22 step stopstrobe 58 59 23 23 proportional se...

Страница 13: ...et to ON 256 auto test light on DR1 1 2 4 8 16 32 64 128 dip switch 1 dip switch 2 dip switch 4 Red on off off illumination level 20 off on off illumination level 30 on on off illumination level 40 of...

Страница 14: ...ter of setting the Auto dip switch to the ON position and selecting a program for it to follow by making a selection from the following dip switches 1 2 4 8 256 There are 4 programs which can be selec...

Страница 15: ...ure the Pin Lite LED as STAND ALONE simply set dip switch Auto to the ON position and select the program you wish to run and the hold and crossfade times to fol low as described in the previous sectio...

Страница 16: ...vigation system of the DR1 in FUNC RED Test red channel menu FUNC MEAS AOO1 MODE o o TESTtest Function test DFSEdefault functions setting To set all the functions at the original values but for DMX ad...

Страница 17: ...o DMXDMX function DMX function mode enter AOO1 enter MA master function Master unit PRG 1 Example program 1 enter PROGprogram To select the number of program to run SPEE speed Memories running time se...

Страница 18: ...ter this the display will show ALIG confirming that you have entered electronic calibration mode ATTENTION The alignment procedure can only be carried out when DMX 512 signal is connected ATTENTION Th...

Страница 19: ...sage indicates that the user has attempted to set the unit to MASTER mode whilst DMX signal is still being received Detach any DMX control signal or remove MASTER mode settings menu AOO1 FUNC enter RE...

Страница 20: ...proper attachment of all connectors cleaning and refastening if necessary All the components of the Pin Lite LED are available as spare parts from your Coemar service centre Accurate description of t...

Страница 21: ...and any cabling for continuity Check the dip switch panel to ensure that no functions are selected which inhibit DMX control Pin Lite LED may be incorrectly addressed Check the DMX addres sing The Pi...

Страница 22: ...A 46042 Castel Goffredo Mantova Italy ph 39 0376 77521 fax 39 0376 780657 info coemar com Coemar si riserva il diritto di apportare modifiche senza preavviso Coemar reserves the right to effect modif...