MAER
:
MASTER Error
This message indicates that the user has attempted to set the unit to master mode whilst DMX signal is till
being received.
SNER
:
LINE SYNCH Error
Check and eventually replace opto-isolator U9.
LAER
:
LAMP Error
The lamp has turned off unexpectedly, without any signal from the controller to do so. The system may
have exceeded the allowable number of attempts to ignite the lamp (7) after which number the system is
designed to protect ignitor, cabling and the lampholder by reducing the incidence of lamp ignition volta-
ges to these components. Check and eventually replace the lamp if it is faulty, damaged, or has exceeded
its lamp life.
EPER
:
EEPROM Error
The EEPROM is either defective or absent; refer to your
coemar
service centre for a replacement compo-
nent.
DTER
:
DATA Error
The fixture has failed to load the configuration data in the system, or has loaded the default settings: repeat
the initialization sequence and if the error continues refer to your
coemar
service center to have your
EEPROM fixed or replaced.
FAER
:
FAN Error
The PCB generates power to the fans and monitors the fan blade speed. If there is a discrepancy between
these two values (rpm and supply) the lamp power will automatically be turned off after 5 seconds of non-
corresponding readings. The fan blades may need cleaning or the fan may need replacing.
The
EXAM
function in the
FUNC
sub-menu many help diagnosis
ADER
:
ADDRESS Error
The projector is not receiving all the DMX channels necessary for its operation. Check the DMX address and
the control console operation.
HEAT
:
LAMP OVERHEAT Indicator
The projector is attempting to ignite a lamp, which is still too hot to strike. Wait until the lamp has cooled
further and then attempt to reignite the lamp.
All the components of the
iCyc 250
are available as spare parts from your
coemar
service centre.
Accurate description of the fixture, model number, and type will assist us in providing for your requirements in an efficient and effec-
tive manner.
25. Spare parts
24 Error messages
29
English