Manual Feature Programming - Feature Bank 2 - 4

1.

Turn the ignition ON.

2.

Press and hold the valet/override button.

3.

Within 10 seconds the system will chirp (3) three times.

4.

Use the valet/override button to advance through each option bank. For
feature programming advance to Feature Bank 2, 3  or 4, which is  (4) four,
(5) five, and (6) six chirps.

5.

Use the transmitter   button to scroll through the selections in each feature
bank, the system will chirp to match the feature number.

6.

Press the transmitter     button to change the desired feature. The LED will
flash indicating the changed feature.

Defaulting All Features: Pressing the   button anytime while in any of the
feature banks will default all features and return you to feature bank 2 - 4 chirps.

NOTE: The system will remain in feature programming mode as long as the
ignition is on, there is no time limit. To exit programming turn the IGNITION OFF.

Set Up & Programming

Transmitter Programming - Feature Bank 1

1.

Turn the ignition ON.

2.

Press and hold the valet/override button.

3.

Within 10 seconds  the system will chirp (3) three times.

4.

Press 1 button of each transmitter you wish to program.

5.

The system will respond with 1 chirp for each accepted transmitter.

6.

Pressing the override button at anytime during programming will advance to
the next bank.

NOTE: The system will exit transmitter programming after 15 seconds of inactivity.

NOTE: This system has 1 button programming which programs all channels of the
system.

NOTE: The system will hold up to 4 transmitters in memory, programming a 5th
transmitter will erase the oldest transmitter in memory.

NOTE: This system has PTN - Programmed Transmitter Notification. Each time the
ignition is turned ON, the LED will flash the number of transmitters programmed to
the system.

Содержание CA 5051

Страница 1: ...1 2010 Audiovox Electronics Corporation All rights reserved PROFESSIONAL SERIES Remote Start with Keyless Entry Installation Guide CA 5051...

Страница 2: ...rnate Harness 9 2 Pin Door Lock Harness 10 Additional Ports 14 Antenna LED Programming Port 14 DBI Port 14 Set Up Programming 15 Transmitter Programming 15 Manual Feature Programming 15 Programming Fe...

Страница 3: ...r hot surfaces Avoid mounting components or routing wires near moving parts Tape or loom wires under hood for protection and appearance Technical Support 800 421 3209 or go to http techservices codesy...

Страница 4: ...ing Light Harness 1 PURPLE STARTER OUTPUT MOTOR SIDE 2 RED BATTERY 12V 3 ORANGE ACCESSORY 1 4 PINK WHITE IGNITION 2 5 RED WHITE BATTERY 12V 6 PINK IGNITION 1 6 PIN START 1 LT GREEN BLACK FACTORY DISAR...

Страница 5: ...icle s trunk release wire at the trunk release switch Verification This wire will register either positive voltage or ground when the trunk release is activated This is a low current output 500mA 4 BL...

Страница 6: ...ill increase as the engine s RPM increases Connect the PURPLE WHITE wire to the negative side of the vehicle ignition coil or fuel injector Fused 12 Volt Battery Source 30 87 87a 86 85 BLUE BLACK Acti...

Страница 7: ...a NOTE Do not ground the BLACK wire with any other vehicle components 3 Pin Parking Light Harness 7 BROWN RED BRAKE INPUT Locate the vehicle s brake light wire at the brake pedal mounted switch Verifi...

Страница 8: ...Volt battery wire NOTE Remove all fuses until all connections are made 3 ORANGE ACCESSORY 1 Locate the vehicle s accessory wire at the ignition switch Verification This wire registers voltage when th...

Страница 9: ...wire to the constant 12 Volt battery wire NOTE Remove all fuses until all connections are made 4 Pin Alternate Harness 1 LT GREEN BLACK FACTORY DISARM PULSE BEFORE START This wire will supply a 200mA...

Страница 10: ...er Output Wire From The C ontrol Module 2 Pin Door Lock Harness 1 BLUE UNLOCK 2 GREEN LOCK The door lock unlock outputs are designed to control several different types of systems which may require add...

Страница 11: ...icle Door Lock Control Relays GREEN Lock Output BLUE Unlock Output Negative Locks Positive Switching Locks All Door Lock and Unlock Locate the lock unlock wire at the vehicle s lock unlock switch Veri...

Страница 12: ...12 Volt Battery Souce GREEN Lock Output BLUE Unlock Output Reverse Polarity Locks X Cut X Cut To Door Lock Motor To Door Lock Motor Negative Multiplexed Locks All Door Lock and Unlock Locate the lock...

Страница 13: ...REEN wires shown in the diagram below using 2 SPDT relays not supplied Lock Unlock Vehicle Door Lock Control Relays GREEN Lock Output BLUE Unlock Output Multiplex Locks 87 87a 86 30 87 87a 86 30 85 85...

Страница 14: ...ut Down Trunk Hatch Open Diesel Glow Plug Input Door Lock Control Passlock Passkey Interface GM Only Dome Light Supervision Transponder Interface Activation Factory Alarm Arm Disarm Manual Arm Disarm...

Страница 15: ...stem will remain in feature programming mode as long as the ignition is on there is no time limit To exit programming turn the IGNITION OFF Set Up Programming Transmitter Programming Feature Bank 1 1...

Страница 16: ...16 2010 Audiovox Electronics Corporation All rights reserved Feature Bank 1 3 Chirps Transmitter Programming Refer to transmitter programming...

Страница 17: ...e unit senses the tach signal the parking lights will begin to flash 6 Allow the vehicle to settle to a normal idle speed 7 Release the valet program push button switch The parking lights will turn on...

Страница 18: ...trols the timing of the BLUE and GREEN lock output wires 1 Second Single 1 second lock pulse single 1 second unlock pulse 3 5 Seconds Single 3 5 second lock pulse single 3 5 second unlock pulse 1 Seco...

Страница 19: ...0mS 40mS 50mS 5 Real Panic Controls the panic out when triggered from the transmitter ON Randomized horn honks when panic is triggered OFF Standard pattern horn honks when panic is triggered Feature B...

Страница 20: ...fter the engine is running may be less than 0 5 volts 6 Crank Time Preset output times for the PURPLE starter wire 1 Second 0 8 Seconds 1 5 Seconds 2 Seconds 4 Seconds 7 Crank Average Crank Time The l...

Страница 21: ...te start will activate and run for the programmed time and shut down every 2 or 3 hours Transmitter Button Functions 1 Way Transmitter Lock Unlock Car Find Panic Start Operation Method Lock X Press an...

Страница 22: ...the parking lights will flash one of the patterns below indicating the shutdown input To manually enter diagnostics and view the last shutdown turn the ignition ON and press and release the button LE...

Страница 23: ...UNLOCK PURPLE STARTER OUTPUT MOTOR SIDE RED BATTERY 12V ORANGE ACCESSORY 1 PINK WHITE IGNITION 2 RED WHITE BATTERY 12V PINK IGNITION 1 BLACK GROUND WHITE RED PARKING LIGHT INPUT WHITE PARKING LIGHT OU...

Страница 24: ...and with RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received inclu...

Отзывы: