920-0451-00 Rev. A
Page 3 of 6
Programming a Lightbar
1. To program a lightbar, load a configuration into the handheld
unit. (See page 2 for review - Writing a Configuration to the
Smart Pro
2. Next, plug the correct programming cable into the lightbar.
(The 1000/1050/1051 series uses the white cable)
3. Press and hold the
Write To Device
button on the SmartPro
for approximately 1 second, then release.
Write to Device
button and power indicator light should stay on.
4. The operation should take 4-5 seconds.
5. Once the power indicator light and
Write to Device
button
light have turned off, it is safe to unplug the cable.
Programming
Reading a Lightbar
1. Plug the correct programming cable into the lightbar central
controller. (The 1000/1050/1051 series uses the white cable)
2. Press and hold the
Read To Device
button on the SmartPro
for approx. 1 second then release.
Read to Device
button
and power indicator light should stay on.
3. Once the power indicator light and the
Read to Device
button
light have turned off, it is safe to unplug the cable.
Troubleshooting
1.
Select Series
drop down menu options do not appear on my
screen.
a. The monitor is too small to show all options. Expand the
window to full screen or use the scroll bar on right side
of screen to see full options.
2. Programming a (i.e. Fast Quad) pattern to my single color
lightbar yields no flashing.
a. Under the
Pattern Selection
tab, check the drop down
Level menus for chosen pattern.
b. Was a Primary Only pattern section selected under the
drop down menu?
c. Scroll to see which section of the drop down is selected.
Make sure a Primary Only pattern is selected.
3. My lightbar doesn’t flash correctly after programming.
a. Check that the
Select Series
drop down at the top has the correct series
chosen.
b. If not, click the drop down to the right and select the proper series bar.
c. Reselect flashes for the various Lamp Position and Level Positions.
4. Nothing changed in my Smart Pro configuration interface after reading a
lightbar.
a. Make sure the connection from SmartPro handheld device is firmly
connected to lightbar before pressing the
Read to Device
button.
b. Make sure USB is not connected to the computer when Smart Pro is
reading from lightbar. Make sure there is no connection to lightbar when
USB is connected to the computer and computer is reading the SmartPro.
c. Make sure USB is firmly connected when computer is reading from device
d. Make sure lights on pushbuttons are lighting when pressed.
(replace batteries if not)
e. If still nothing changes, try rebooting your computer.
1000/1050/1051
800/950/951
4 - AAA batteries (not included) must be inserted into the Smart-
Pro prior to programming.
Содержание SmartPro