920-9139-00 Rev. E
Page 3 of 4
INSTALLATION OF 4 SD24
™
USING PATTERN SELECT SWITCH PANEL(OPTIONAL) ON DASHBOARD.
FUSE
CHASSIS
GR
OUND
+12V
BL
UE
RED
BLA
CK
ON/OFF
PATTERN
SELECT
RED
BLACK
BLUE
YELLOW
RED
BLACK
BLUE
YELLOW
YELL
OW
TO +V
RED
BLACK
BLUE
RED
BLACK
BLUE
YELLOW
YELL
OW
TO -
GR
OUND
YELL
OW
TO -
GR
OUND
YELL
OW
TO +V
ALTERNATE FLASHING
ALTERNATE FLASHING
AL
TERNA
TE FLASHING
AL
TERNA
TE FLASHING
ORANGE
POWER-UP RESET:
After installing the system it is best to do a POWER-UP RESET the first time
to ensure all heads are in sync.
Touch
BLUE
wires to +V (
RED
wire) while applying power.
Release
BLUE
wires. All heads will reset to Pattern #2.
If you have installed a pattern select push-button, press and hold
pattern select while turning power switch ON.
To select a flash pattern, touch
BLUE
to +V or press pattern select switch to
increment the flash pattern. The heads will remember the selected pattern
even if power is removed.
STANDARD PATTERNS
#
Pattern:
Frequency:
Description:
SAE
J 595
Class 1
CA
T13
Class B
1
Quad Flash
1.25 Hz
75 Quad Flashes Per Minute
X
X
2
Double Flash
1.25 Hz
75 Double Flashes Per Minute
X
X
3
Triple Flash
1.53 Hz
92.3 Triple Flashes Per Minute
X
X
4
DeciBlast
1.42 Hz
85.5 Deci Flashes Per Minute
X
X
5
Single Flash
1.25 Hz
75 Single Flashes Per Minute
X
X
6
Mega Flash
1.90 Hz
114 Single Flashes Per Minute
X
X
7
Burst
1.37 Hz
82.5 Burst Flashes Per Minute
X
X
8
Steady On
Steady on.
Split Color = Fast Mega
CYCLE PATTERNS
9
Cycle All
Cycle through patterns 1 to 7
X
X
10
Double-Burst
2 Double, 2 Burst cycle
X
X
11
Cycle Classic
1 Double, 1 Quad, 4 Mega cycle
X
X
12
Quad-Mega
3 Quad, 5 Mega cycle
X
X
13
Single-Quad
2 Single, 2 Quad cycle
X
X
14
DeciBlast-Quad
2 DeciBlast, 2 Quad cycle
X
X
15
Single-Triple-DeciBlast
2 Single, 2 Triple, 2 DeciBlast cycle
X
X
16
Mega-Burst
1 Mega, 1 Burst cycle
X
X
STANDARD PATTERNS:
The 3510 ships with sixteen patterns enabled. Standard patterns 1 through
8 are compatible with older BULL LED™ and HIDE-A-LED™ products.
CYCLE PATTERNS:
You may revert to patterns 1 through 8 by following this procedure:
1) Touch
BLUE
wires to +V (
RED
wire) while applying power.
If you have installed a pattern select push-button, press and hold
pattern select while turning power switch ON.
2) Hold
BLUE
wires on +V for 5 SECONDS (heads will not be flashing
during this time). After 5 SECONDS the heads will flash once or twice to
indicate the flash pattern list that has been selected:
ONE FLASH
= Standard Patterns only.
TWO FLASHES
= St Cycle Patterns.
3) Remove the
BLUE
wires from +V (or release push-button).
You may switch the pattern set at any time as many times as you wish. All
heads will remember the pattern set that was selected even when power is
removed.
Flash Patterns:
HEAD NOT FLASHING:
Check the RED and BLACK wires for a reversed connection. (Reverse
connection will not damage the unit). Check RED and BLACK wires for
either a bad splice or a corroded ground connection.
HEADS NOT SYNCHRONIZING:
Check for a short circuit on the BLUE wire to V or GROUND.
Saltwater on the wire connections will short circuit the sync signal on the
BLUE wire. Check for non-functional heads in the system. If any one of
the heads has a bad GROUND connection it can cause the sync signal to
become corrupted. If any one of the heads has it’s RED and BLACK wires
reverse connected it will corrupt the sync signal.
FLASH PATTERN CHANGING:
If the flash pattern changes on it’s own there may be an intermittent short
between the BLUE wire and +V. Check for water in the wiring connections.
If any one of the heads in the system has an intermittent GROUND
connection it can also cause the flash pattern to change.
Troubleshooting:
FIGURE 3