920-0661-00 Rev. C
Page 2 of 8
Wire: M180LS
1
Light Head
1
Multi-Mount Base:
Includes:
2- M4x25 Sheet metal screws
1
1-EVA foam gasket
1
1-BEZEL
CONTENTS:
Input Voltage
12-24VDC
Work Current
M180L = 1.7A Max @ DC12V
M180LMC = 1.7A Max @ DC12V
SPECIFICATIONS:
Important!
This unit is a safety device and it must be
connected to its own separate, fused power source to assure its
continued operation should any other electrical accessory fail.
Caution:
When drilling into any vehicle surface, make sure the
area is free from any electrical wires, fuel lines, vehicle upholstery,
etc. that could be damaged
RED: Positive(need to add 2A Fuse)
BLACK: Negative
BLUE: Pattern Select to Negative and Dimming to Positive
YELLOW: Synchronized Function
(Up to 8 units can be Synchronized)
ORANGE: Takedown Light Operation
Operation Environment:
Ambient Temperature:
-30 to 50°C
Wire: M180LMC
RED: Positive, Colors 1 & 3 (need to add 5A Fuse)
WHITE: Positive, Colors 2 & 4 (need to add 5A Fuse)
BLACK: Negative
BLUE: Pattern Select to Negative and Dimming to Positive
YELLOW: Synchronized Function
(Up to 8 units can be Synchronized)
ORANGE: Takedown Light Operation
RED
WHITE
PRODUCT
1 & 3 COLORS
2 & 4 COLORS
M180LMC-AW
AMBER
WHITE
M180LMC-BW
BLUE
WHITE
M180LMC-RB
RED
BLUE
M180LMC-RW
RED
WHITE
M180LMC-BA
AMBER
BLUE
M180LMC-RA
AMBER
RED
Pattern Select Operation:
The light flash pattern may be changed by holding the blue wire to ground for the following intervals:
1 second: increment flash pattern
3 seconds: decrement flash pattern
5 seconds: reset to default
7 seconds: set to last flash pattern
Note:
The blue wire must be disconnected from any voltage when operating except when changing flash patterns or
activating dim.