Page 48
Measure the Modulation Fidelity of the transmitter as shown in Figure 5-35. The transmitter should not
read more than 5% Modulation Fidelity. If the Modulation Fidelity is more than 5%, the transmitter will
need to be returned to the factory for service. The high alarm point is set at 5%.
Figure 5-35: Transmitter Modulation Fidelity Measurement
Enter the C4FM Modulation Fidelity reading on the MT-4E Test Sheet.