background image

Ku-Band BUC systems

12-50176-EN Issue 2, December 2010

Page 15 of 18

Flange kits

Table 7:

Kit, Flange, WR75, Thick groove (15-40172)

Description

Component part number

Nut, M4, Stainless steel, Hex (qty 5)

31-24000-080

Washer, M4, Stainless steel, Normal (qty 10)

31-24001-080

Washer, M4, Stainless steel, Spring (qty 5)

31-24001-580

Screw, M4 × 10, Stainless steel, Socket cap (qty 5)

31-24010-901

Screw, M4 × 12, Stainless steel, Socket cap (qty 5)

31-24012-980

Screw, M4 × 16, Stainless steel, Socket cap (qty 5)

31-24016-980

Gasket, W/G, Circular cross-section, 3/32, WR75

78-23024

Table 8:

Kit, Flange, WR75, Universal (15-40174)

Description

Component part number

Nut, M4, Stainless steel, Hex (qty 5)

31-24000-080

Washer, M4, Stainless steel, Normal (qty 5)

31-24001-080

Washer, M4, Stainless steel, Spring (qty 5)

31-24001-580

Screw, M4 × 10, Stainless steel, Socket cap (qty 5)

31-24010-901

Screw, M4 × 12, Stainless steel, Socket cap (qty 5)

31-24012-980

Screw, M4 × 16, Stainless steel, Socket cap (qty 5)

31-24016-980

Gasket, W/G, Rectangular cross-section, WR75

78-23022

Gasket, W/G, Circular cross-section, 1/16, WR75

78-23023

Gasket, W/G, Circular cross-section, 3/32, WR75

78-23024

Содержание 4908-MINIBUC

Страница 1: ...au INSTALLATION Ku Band BUC systems Overview Codan provides a range of BUCs of varying power ranges that operate in basic single BUC systems or redundancy systems These BUCs operate in the C Band and...

Страница 2: ...equirements and safety notices please see the reference manual for the product WARNING All equipment that is mounted outdoors must be adequately weatherproofed Use self amalgamating tape to seal conne...

Страница 3: ...l power to the site Install any other mounting structures Connect the equipment together using appropriate cables Set up the indoor and outdoor equipment to station parameters See page 12 Essential ri...

Страница 4: ...universal boom mounting kit suitable for the Codan range of L M RBUCs Contact your antenna manufacturer if you have specific installation requirements It is recommended that BUCs are installed as clo...

Страница 5: ...ounted on the pole at the base of the antenna with the mounting hardware supplied DC may be supplied to the BUC via the BIAS T connector on the 6580B using the Tx IF coaxial cable or via the AUX termi...

Страница 6: ...power cable or re terminate the cable supplied Table 1 lists the pin connections and describes the input functions available on the DC INPUT connector on the BUC WARNING Before applying power to the B...

Страница 7: ...ins cable or re terminate the cable supplied Table 2 lists the pin connections and describes the input functions available on the AC INPUT connector on the BUC WARNING Voltages outside of these limits...

Страница 8: ...C pipe for example or supported by an overhead catenary wire If the transmit and receive IF coaxial cables are identical mark the cables at each end before you install them Also ensure that there is e...

Страница 9: ...apillary action Water and sometimes dust within a connection or cable attenuates the signal In extreme cases water causes a short circuit and corrosion within the connection or cable If water has ente...

Страница 10: ...antenna AC mains Tx to antenna L Band Tx IF 24 48 V DC power DC powered BUC only 10 MHz Ref FSK M C L Band Rx IF 15 V DC power nominal 10 MHz Ref RS232 422 485 M C L Band Modem TRF BUC LNB External A...

Страница 11: ...nsions for your BUC M C Rx from antenna AC mains Tx to antenna L Band Tx IF 10 MHz Ref FSK M C L Band Rx IF 15 V DC power nominal 10 MHz Ref RS232 422 485 M C L Band Modem TRF BUC LNB Data External in...

Страница 12: ...on In the case of lightning strikes large ground currents occur for several hundred metres around a strike area causing large voltage potentials between separate earth points For this reason some ligh...

Страница 13: ...y 36 32 00800 080 Washer M8 Stainless steel Flat qty 36 32 00801 080 Washer M8 Stainless steel Spring qty 36 32 00801 280 Bolt M8 50 Stainless steel Hex qty 4 32 00850 080 Table 4 Kit Mounting 8 to 12...

Страница 14: ...sher M8 Stainless steel Spring qty 14 32 00801 280 Screw M8 50 Stainless steel Hex qty 4 32 00850 080 Table 6 Kit Mounting 12 Pole PSU 15 40147 Description Component part number Rod Threaded M8 375 mm...

Страница 15: ...steel Socket cap qty 5 31 24016 980 Gasket W G Circular cross section 3 32 WR75 78 23024 Table 8 Kit Flange WR75 Universal 15 40174 Description Component part number Nut M4 Stainless steel Hex qty 5...

Страница 16: ...Sealing kits Table 9 Kit Connector Sealing 15 40202 Description Component part number Application Note Sealing N type and MS connectors in satellite equipment installations 17 60094 Tape Vinyl Elec 19...

Страница 17: ...ng Universal to 100 W BUC 15 42072 001 sheet 1 Boom Mounting Universal 7580 PSU 15 42072 001 sheet 2 Pole Mounting 8 to 12 RBUC C Ku 15 42098 001 PSU 5586 8 pole 15 40128 001 PSU SSPA 12 pole 15 40147...

Страница 18: ...Ku Band BUC systems Page 18 of 18 12 50176 EN Issue 2 December 2010 This page has been left blank intentionally...

Страница 19: ...15 42072 001 sheet 1...

Страница 20: ...15 42072 001 sheet 2...

Страница 21: ...15 42098 001...

Страница 22: ...15 40128 001...

Страница 23: ...15 40147 001...

Страница 24: ...01 01192 CODAN...

Страница 25: ...01 01828...

Страница 26: ...01 01302...

Страница 27: ...01 01689...

Страница 28: ...01 01785...

Отзывы: