Coda v12 Скачать руководство пользователя страница 4

VOLTAGE                       FUSE TYPE

   100V           8 AMP    SLOW BLOW  5 x 20mm

   120V           8 AMP    SLOW BLOW  5 x 20mm

   220V           4 AMP    SLOW BLOW  5 x 20mm

   240V           4 AMP    SLOW BLOW  5 x 20mm

FOR CONTINUED PROTECTION

AGAINST SHOCK OR FIRE:

1. REPLACE FUSE WITH SAME

TYPE AND RATING

2. DO NOT EXPOSE THIS UNIT

TO RAIN OR MOISTURE

UNBRIDGED

UNBALANCED

BALANCED

UNBALANCED

BALANCED

MAIN POWER

OFF

ON

AC LINE FUSE CHART

FUSE AND VOLTAGE SELECTOR

FUSE VALUE -SEE FUSE CHART

VOLTAGE SELECTION-

SEE OPERATION MANUAL

!

NOTE

SEE SERIAL TAG FOR POWER

REQUIREMENTS, REMOVE POWER

CORD BEFORE CHANGING

FUSE OR LINE VOLTAGE

!

120

AC LINE INPUT

~

T E C H N O L O G I E S   I N C .

MODEL

SERIAL NUMBER

VOLTAGE REQUIREMENT

MANUFACTURED IN THE USA

 HZ

POWER REQUIREMENT

                     VA

TO PREVENT ELECTRIC SHOCK, DO NOT

REMOVE COVER. NO USER SERVICEABLE

PARTS INSIDE. REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

CH 1 OUTPUT

CH 2 OUTPUT

CH 3 OUTPUT

CH 4 OUTPUT

CH 1 INPUTS

CH 2 INPUTS

CH 3 INPUTS

CH 4 INPUTS

UNBRIDGED

C A U T I O N

WA R N I N G

!

BRIDGED-CHANNEL 1

AND  CHANNEL 2

BRIDGED-CHANNEL 3

AND  CHANNEL 4

BRIDGED-DO NOT USE GROUNDS

BRIDGED-DO NOT USE GROUNDS

DO NOT ALLOW AMPLIFIER OUTPUTS

TO COMMON BETWEEN CHANNELS,

OR CONTACT CHASSIS OR INPUT

GROUNDS,  OR TO BE CONNECTED

TO ANY ACTIVE CURRENT SOURCE.

                     THIS PRODUCT
                     IS DESIGNED,
                     ENGINEERED
AND BUILT IN THE UNITED
STATES OF AMERICA.

BRIDGED

INPUT

BRIDGED

INPUT

 

 3

INSTALLATION  CONNECTIONS

The first section of the installation instructions for the AMPLIFIER v12 is a diagram of the

default four channel configuration required to bring this amplifier into an operating

mode. These brief steps will allow you to begin operating your system. Make sure during

installation that the main AC power switch on the back of the AMPLIFIER v12 is turned off.

While the diagram may be self explanatory,  we strongly recommend that you read the

detailed instructions following this introductory section.

SPEAKER 4

SPEAKER 1

PREAMPLIFIER

PREAMPLIFIER

SPEAKER 3

SPEAKER 2

Содержание v12

Страница 1: ...UAL T E C H N O L O G I E S I N C ADDRESS 9 4 1 2 3 13 16 15 14 12 SAFETY PRECAUTIONS INSTALLATION CONNECTIONS INTRODUCTION DETAILED INSTALLATION DESIGN PHILOSOPHY TECHNICAL DATA CARE and HANDLING WAR...

Страница 2: ...K 1 SAFETY PRECAUTIONS WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE TO AVOID ELECTRICAL SHOCK DO NOT OPEN THE UNIT REFER SERVICING TO QUALIFIED PERSONNEL Never i...

Страница 3: ...ort to provide the listener with unmatched sound quality design and construction In order to operate your amplifier properly and to realize all of the capabilites of the AMPLIFIER v12 we recommend tha...

Страница 4: ...UT CH 4 OUTPUT CH 1 INPUTS CH 2 INPUTS CH 3 INPUTS CH 4 INPUTS UNBRIDGED CAUTION WARNING BRIDGED CHANNEL 1 AND CHANNEL 2 BRIDGED CHANNEL 3 AND CHANNEL 4 BRIDGED DO NOT USE GROUNDS BRIDGED DO NOT USE G...

Страница 5: ...n the back panel of the AMPLIFIER v10 Note the correct channel orientation The function and channel markings on the rear panel correspond to the front panel controls and their signal paths 1 The MODE...

Страница 6: ...the balanced and unbalanced inputs 3 These LEDs when lit indicate that the bias is activated in the AMPLIFIER v12 4 This two color LED indicates that the main power is on When it is green the balanced...

Страница 7: ...Coda products as well as many other audio and video components For instructions on the remotes other capabilities refer to the Universal Remote Control Manual 1 The POWER button turns on the bias and...

Страница 8: ...ER v12 OFF BEFORE ALTERING THE MODE SWITCH OR CONNECTING OR DISCONNECTING ANY CABLES The bridging switch commons the inputs of the AMPLIFIER v12 were pin 2 of the left XLR commons with pin 3 of the ri...

Страница 9: ...ECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CH 1 OUTPUT CH 2 OUTPUT CH 3 OUTPUT CH 4 OUTPUT CH 1 INPUTS CH 2 INPUTS CH 3 INPUTS CH...

Страница 10: ...r and over 144 000 uf of capacitance with very low ESR and inductance is used For optimum performance and reliability all circuity remains continuosly powered Thespecificationsareconsistentwithwhatwou...

Страница 11: ...The above attributes result in a amplifier of such extreme linearity and bandwidth that no overall feedback correction is required or used One advantage of this is a high degree of immunity from inte...

Страница 12: ...electrolytics used are in the power supply where large numbers provide enormous filtering capacitance for the supply 5 Semiconductors There are no integrated circuits IC in the signal path Very high q...

Страница 13: ...4 Ohms through 8 Ohms Gain 32dB Maximum Current 60 Amperes peak Noise 100dB referenced to rated output Input Impedance 1k Ohms unbalanced 1k Ohms balanced Output Impedance 15 Ohms from 20Hz to 20kHz A...

Страница 14: ...um is a medium hardness metal and can be scratched by harder tool steels and the surface can be easily marred if the amplifier is set face down on a hard surface Do not rest the amplifier on it s face...

Страница 15: ...SACRAMENTO CA 95826 USA T E C H N O L O G I E S I N C 7850 CUCAMONGA AVENUE 31 phone 01 916 383 3653 fax 01 916 455 3653 on the web at CODA CC email us at info coda cc...