Coda 40.0 Скачать руководство пользователя страница 2

!

CAUTION

CAUTION

WARNING

WARNING

!

                                                 SERVICING TO QUALIFIED SERVICE

                                       CAUTION

:  TO PREVENT ELECTRIC SHOCK,

                                                 DO NOT REMOVE COVER.  NO USER

                                                 SERVICEABLE PARTS INSIDE,  REFER

                                                 PERSONNEL.

THIS SYMBOL IS INTENDED TO ALERT
YOU OF THE PRESENCE OF IMPORTANT
OPERATING AND MAINTENANCE
INSTRUCTIONS IN THE LITERATURE
ACCOMPANYING THE UNIT.

THIS SYMBOL IS TO ALERT YOU OF THE
PRESENCE OF UNINSULATED DANGER-
OUS VOLTAGE WITHIN THE UNIT'S
ENCLOSURE THAT MAY BE OF SUFFI-
CIENT MAGNITUDE TO CONSTITUTE A
RISK OF ELECTRIC SHOCK.

                     WARNING:

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS UNIT TO RAIN OR MOISTURE. TO
AVOID ELECTRICAL SHOCK,  DO NOT OPEN THE
UNIT.  REFER SERVICING TO QUALIFIED PERSONNEL.

Never install or remove the power cord from the

 

chassis

unless it has been disconnected from the AC power source
first.
Never pull on the power cord when removing it from an AC
power source. Grasp it by the plug.
Do not leave the power cord connected to an AC power
source unless it is connected to the unit.
It is recommended that during extended periods of nonuse
the unit's power cord be unplugged from its AC power
source.
Route the AC power cord so that it will not be damaged or
walked on.

CAUTION -

-

-

-

-

SAFETY PRECAUTIONS

1

Содержание 40.0

Страница 1: ...5 14 12 SAFETY PRECAUTIONS INITIAL SETUP INTRODUCTION DETAILED INSTALLATION DESIGN PHILOSOPHY TECHNICAL DATA CARE AND HANDLING WARRANTY DISCLAIMER WARRANTY REGISTRATION BIAS INPUT LEFT RIGHT XLR GN RC...

Страница 2: ...CK WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE TO AVOID ELECTRICAL SHOCK DO NOT OPEN THE UNIT REFER SERVICING TO QUALIFIED PERSONNEL Never install or remove the...

Страница 3: ...to provide the listener with unmatched sound quality through superb design and construction Although its operation is fairly simple in order to operate your amplifier properly and to realize all of t...

Страница 4: ...O G I E S I N C MODEL SERIAL NUMBER VOL TAGE REQUIREMENT MANUF ACTURED IN THE USA HZ POWER REQUIREMENT V A FOR CONTINUED PROTECTION AGAINST SHOCK OR FIRE 1 REPLACE FUSE WITH SAME TYPE AND RA TING 2 DO...

Страница 5: ...to the power cable provided with the amplifier After making the appropriate connections insert the three prong safety plug into an appropriate AC power source Once the AMPLIFIER S5 is properly connec...

Страница 6: ...tton enables the bias effectively turning on the amplifier s components and opens shunting relays that mute the input Note If a power interruption occurs to the system the amplifier will power on with...

Страница 7: ...be connected and the bridged mode input must be a balanced signal connected to the XLR receptacle labeled BRIDGED INPUT Bridged mode will not operate correctly with an input adapted from an unbalance...

Страница 8: ...REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION CAUTION W W ARNING ARNING LEFT CHANNEL UNBALANCED INPUTS BALANCED RIGHT CHANNEL INPUTS UNBALANCED B...

Страница 9: ...ns correspond to the buttons on the amplifier s faceplate For reference BIAS toggles the state of the bias circuitry standby on and off and INPUT toggles between the balanced and unbalanced audio inpu...

Страница 10: ...y takes a very direct approach to high performance First top quality toroidal transformers and over 200 000uf of capacitance with very low ESR and inductance are used For optimum performance and relia...

Страница 11: ...e Theseattributes result in a amplifier of such extreme linearity and bandwidth that no overall feedback correction is required or used One advantage of this is a high degree of immunity from interact...

Страница 12: ...o electrolytic capacitors are used except in the power supply where several high capacitance electrolytics provide outstanding filtering of the supply output All semiconductor devices are of very high...

Страница 13: ...lass AB 8 Ohms Frequency Response DC to 3dB 100kHz Distortion 02 percent from 10 Hz to 20kHz rated power Gain 32dB Maximum Current 100 Amperes peak Noise 120dB referenced to rated output Input Impedan...

Страница 14: ...etal and can be scratched by harder tool steels and the grained surface can be easily marred if the amplifier is set face down on a hard surface Do not rest the amplifier on it s faceplate The amplifi...

Страница 15: ...nt unit will be visually similar to the original product iii Exclusion of Coverage Coda Technologies is not obligated to service the product in certain conditions as according to the following subsect...

Страница 16: ...Name Address City State Zip Phone Fill in this registration sheet and fax or mail it to Coda Technologies to ensure you are in our warranty system This will facilitate warranty service should it beco...

Страница 17: ...Name Address City State Zip Phone Fill in this registration sheet and fax or mail it to Coda Technologies to ensure you are in our warranty system This will facilitate warranty service should it beco...

Страница 18: ...SACRAMENTO CA 95826 USA T E C H N O L O G I E S I N C 7850 CUCAMONGA AVENUE 34 phone 01 916 383 3653 fax 01 916 455 3653 on the web at CODA CC email us at info coda cc...

Отзывы: