Coda 33.0 Скачать руководство пользователя страница 4

Stereo Amplifier Configuration

WARNING:

 Please ensure that the power switch is turned OFF while you are connecting the 

amplifier.  Connecting  or  disconnecting  cables  while  the  amplifier  is  powered  on  could 
cause damage to your speakers.

NOTE:

  Ensure  that  the  mode  switch  located  between  the  input  jacks  on  the  rear  of  the 

amplifier is set to the stereo position for normal operation. Bridged operation is explained on 
page 7.

The diagram below shows the default connections necessary to operate the 33.0 as a 
stereo amplifier. This is the simplest and most common mode of operation, and the quickest 
way to get started. Once these connections are made you can turn the power switch on, 
enable the bias from the front panel and start listening to your amplifier.

For simplicity this diagram shows an audio configuration using balanced interconnects. This 
is the default input mode of the amplifier. Unbalanced operation requires that you set the 
appropriate input mode as detailed on page 5.

INITIAL SETUP

3

LEFT SPEAKER

RIGHT SPEAKER

PREAMPLIFIER

AMPLIFIER 33

!

FOR CONTINUED PROTECTION AGAINST 

SHOCK OR FIRE HAZARD,DO NOT EXPOSE 

THIS UNIT TO RAIN OR MOISTURE.

          AC LINE INPUT

   SEE SERIAL T AG FOR

POWER REQUIREMENTS  

~

UNBALANCED INPUT

RIGHT

LEFT

COMPACT DISC

RIGHT

LEFT

TUNER

RIGHT

LEFT

VIDEO

RIGHT

LEFT

MONITOR

RIGHT

LEFT

RIGHT

LEFT

IN

OUT

PROCESSOR

RIGHT

LEFT

RIGHT

LEFT

IN

OUT

VIDEO

RIGHT

LEFT

UNBALANCED OUTPUT

RIGHT

LEFT

T E C H N O L O G I E S   I N C .

MODEL

SERIAL NUMBER

VOLTAGE REQUIREMENT

MANUFACTURED IN THE USA

 HZ

POWER REQUIREMENT

                     VA

FOR CONTINUED PROTECTION
AGAINST SHOCK OR FIRE:
1. REPLACE FUSE WITH SAME
TYPE AND RATING
2. DO NOT EXPOSE THIS UNIT
TO RAIN OR MOISTURE

BRIDGED

STEREO

DO NOT ALLOW AMPLIFIER OUTPUTS

TO COMMON BETWEEN CHANNELS,

OR CONTACT CHASSIS OR INPUT

GROUNDS,  OR TO BE CONNECTED

TO ANY ACTIVE CURRENT SOURCE.

MAIN POWER

OFF

ON

AC LINE FUSE CHART

FUSE AND VOLTAGE SELECTOR

FUSE VALUE -SEE FUSE CHART

VOLTAGE SELECTION-

SEE OPERATION MANUAL

!

NOTE

SEE SERIAL TAG FOR POWER

REQUIREMENTS, REMOVE POWER

CORD BEFORE CHANGING

FUSE OR LINE VOLTAGE

!

12

0

AC LINE INPUT

~

TO PREVENT ELECTRIC SHOCK, DO NOT

REMOVE COVER. NO USER SERVICEABLE

PARTS INSIDE. REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

CAUTION

CAUTION

W

W

ARNING

ARNING

!

LEFT CHANNEL

UNBALANCED

INPUTS

BALANCED

RIGHT CHANNEL

INPUTS
UNBALANCED

BALANCED

MODE

PUSH

PUSH

VOLTAGE                       FUSE TYPE

   100V

   120V

   220V

   240V

12 AMP    SLOW BLOW 5 x 20mm

  6 AMP    SLOW BLOW 5 x 20mm

DO  NOT  CONNECT  AMPLIFIER  OUTPUT 
TERMINALS 

TOGETHER. 

CONNECT 

AMPLIFIER OUTPUT  TERMINALS ONLY TO 
SPEAKERS.

FOR CONTINUED PROTECTION AGAINST 
SHOCK OR FIRE:
REPLACE  FUSE  WITH  SAME  TYPE  AND 
RATING.  DO  NOT  EXPOSE  THIS  UNIT  TO 
RAIN OR MOISTURE

SEE SERIAL TAG FOR POWER REQUIREMENTS. 

REMOVE POWER CORD BEFORE CHANGING FUSE OR LINE VOLTAGE.

AC LINE INPUT

MAIN POWER

FUSE / VOLTAGE SELECTOR

READ THE BRIDGING SECTION OF THE OPERATING MANUAL OR CONTACT YOUR CODA AUTHORIZED 

DEALER TO SET THE BRIDGING SWITCHES

BRIDGED MODE 

16 AMP

16 AMP

8 AMP

8 AMP

UNBALANCED

BRIDGED

INPUTS

INPUTS

BALANCED

BALANCED

INPUTS

UNBALANCED

PUSH

PUSH

230

Содержание 33.0

Страница 1: ...5 14 12 SAFETY PRECAUTIONS INITIAL SETUP INTRODUCTION DETAILED INSTALLATION DESIGN PHILOSOPHY TECHNICAL DATA CARE AND HANDLING WARRANTY DISCLAIMER WARRANTY REGISTRATION BIAS INPUT LEFT RIGHT XLR GN RC...

Страница 2: ...CK WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE TO AVOID ELECTRICAL SHOCK DO NOT OPEN THE UNIT REFER SERVICING TO QUALIFIED PERSONNEL Never install or remove the...

Страница 3: ...rt to provide the listener with unmatched sound quality through superb design and construction Although its operation is fairly simple in order to operate your amplifier properly and to realize all of...

Страница 4: ...C H N O L O G I E S I N C MODEL SERIAL NUMBER VOLTAGE REQUIREMENT MANUFACTURED IN THE USA HZ POWER REQUIREMENT VA FOR CONTINUED PROTECTION AGAINST SHOCK OR FIRE 1 REPLACE FUSE WITH SAME TYPE AND RATI...

Страница 5: ...to the power cable provided with the amplifier After making the appropriate connections insert the three prong safety plug into an appropriate AC power source Once the AMPLIFIER S5 is properly connec...

Страница 6: ...tton enables the bias effectively turning on the amplifier s components and opens shunting relays that mute the input Note If a power interruption occurs to the system the amplifier will power on with...

Страница 7: ...be connected and the bridged mode input must be a balanced signal connected to the XLR receptacle labeled BRIDGED INPUT Bridged mode will not operate correctly with an input adapted from an unbalance...

Страница 8: ...REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION CAUTION W W ARNING ARNING LEFT CHANNEL UNBALANCED INPUTS BALANCED RIGHT CHANNEL INPUTS UNBALANCED B...

Страница 9: ...ns correspond to the buttons on the amplifier s faceplate For reference BIAS toggles the state of the bias circuitry standby on and off and INPUT toggles between the balanced and unbalanced audio inpu...

Страница 10: ...y takes a very direct approach to high performance First top quality toroidal transformers and over 184 000uf of capacitance with very low ESR and inductance are used For optimum performance and relia...

Страница 11: ...e filtering of all AC ripple Theseattributes result in a amplifier of such extreme linearity and bandwidth that no overall feedback correction is required or used One advantage of this is a high degre...

Страница 12: ...o electrolytic capacitors are used except in the power supply where several high capacitance electrolytics provide outstanding filtering of the supply output All semiconductor devices are of very high...

Страница 13: ...lass AB 8 Ohms Frequency Response DC to 3dB 100kHz Distortion 02 percent from 10 Hz to 20kHz rated power Gain 32dB Maximum Current 100 Amperes peak Noise 120dB referenced to rated output Input Impedan...

Страница 14: ...etal and can be scratched by harder tool steels and the grained surface can be easily marred if the amplifier is set face down on a hard surface Do not rest the amplifier on it s faceplate The amplifi...

Страница 15: ...mponent failure will be corrected by Coda Technologies without charge for parts or labor for a period of ten years from date of original purchase Coda Technologies will provide for surface transportat...

Страница 16: ...Name Address City State Zip Phone Fill in this registration sheet and fax or mail it to Coda Technologies to ensure you are in our warranty system This will facilitate warranty service should it beco...

Страница 17: ...SACRAMENTO CA 95826 USA T E C H N O L O G I E S I N C 7850 CUCAMONGA AVENUE 34 phone 01 916 383 3653 fax 01 916 455 3653 on the web at CODA CC email us at info coda cc...