background image

1.  To reduce the risk of electric shock, insure 

electricity has been turned off at the circuit 
breaker or fuse box before beginning.

2.  All wiring must be in accordance with the 

National Electrical Code and local 
electrical codes. Electrical installation 
should be performed by a qualified 
licensed electrician.

3.   

WARNING:

 To reduce the risk of electrical 

shock and fire, do not use this fan with any 
solid-state fan speed control device.

4. 

WARNING:

 To reduce the risk of fire, 

electric shock, or other personal injury, 
mount fan only on an outlet box or 
supporting system marked acceptable for 
fan support of 35 lbs (15.9 kg) or less and 
use mounting screws provided with the 
outlet box. Most outlet boxes commonly 
used for the support of lighting fixtures are 
not acceptable for fan support and may 
need to be replaced. Consult a qualified 
electrician if in doubt.

5.  The outlet box and support structure must 

be securely mounted and capable of 
reliably supporting a minimum of 50 
pounds. Use only UL Listed outlet boxes 
marked 

"FOR FAN SUPPORT"

.

6.   The fan must be mounted with a minimum 

of 7 feet clearance from the trailing edge 
of the blades to the floor.

7.  Do not operate reversing switch while fan 

blades are in motion. Fan must be turned 
off and blades stopped before reversing 
blade direction.

8.  Avoid placing objects in the path of the 

blades.

9.   To avoid personal injury or damage to the 

fan and other items, be cautious when 
working around or cleaning the fan.

10. Do not use water or detergents when 

cleaning the fan or fan blades. A dry dust 
cloth or lightly dampened cloth will be 
suitable for most cleaning.

11. After marking electrical connections, 

spliced conductors should be turned 
upward and pushed carefully up into 
outlet box. The wires should be spread 
apart with the grounded conductor and 
the equipment-grounding conductor on 
one side of the outlet box.

12. Electrical diagrams are reference only. 

Light kit that are not packed with the fan 
must be UL Listed and marked suitable 
for use with the model fan you are 
installing. Switches must be UL General 
Use Switches. Refer to the Instructions 
packaged with the light kits and switches 
for proper assembly.

2

3. SAFETY RULES

WARNING

TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK OR PERSONAL 

INJURY, MOUNT FAN TO OUTLET 

BOX MARKED "ACCEPTABLE FOR 

FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL 

INJURY, DO NOT BEND THE BLADE 

BRACKETS (ALSO REFERRED TO AS 

FLANGES) DURING ASSEMBLY OR 

AFTER INSTALLATION. DO NOT INSERT 

OBJECTS IN THE PATH OF THE 

BLADES.

Содержание BAINBRIDGE CF-A-BA

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS BAINBRIDGE CEILING FAN INSTALLATION AND OPERATION INSTRUCTION FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552 MODEL CF A BA...

Страница 2: ...ade bracket set 5 g Mounting plate h Light kit assembly i Glass shades 3 j Fluorescent lamps 3 k Pull chain and fob 2 l Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire...

Страница 3: ...Do not operate reversing switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid...

Страница 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade cl...

Страница 5: ...p 6 Route wires exiting from the top of the fan motor through the collar cover canopy cover canopy and then through the ball downrod Fig 7 Step 7 Align the holes at the bottom of the downrod with the...

Страница 6: ...utlet box and the black and the blue wires are on the other side Step 5 Turn the connecting nuts upward and push the wiring into the outlet box Figures 10 and 11 illustrate the wiring connections for...

Страница 7: ...Warning Make sure tab at bottom of hanger bracket is properly seated in groove of hanger ball before attaching canopy to bracket Failure to properly seat tab in groove could cause damage to electrical...

Страница 8: ...2 screws Do not remove 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the...

Страница 9: ...es back into the light kit assembly then install the light kit assembly onto the mounting plate with 3 screws previously removed Be sure to tighten all screws Fig 15 4 Remove the lock ring from the so...

Страница 10: ...cool weather depend on factors such as the room size Ceiling height number of fans and so on 2 Light kit pull chain it controls the light kit in ON or OFF The slide switch controls directions forward...

Страница 11: ...o remove fan from ceiling 2 Clean your fan periodically to help maintain its new appearance over the years Use only a soft brush or lint free cloth to avoid scratching the finish The plating is sealed...

Страница 12: ...e variable speed controls If you have installed this type of control choose and install another type of control 7 Make sure the upper canopy is a short distance from the ceiling It should not touch th...