2
Function
Description
Add
1.
Have Z-Wave
TM
controller entered inclusion mode.
2.
Pressing tamper key three times within 1.5 seconds to enter
the inclusion mode.
3.
After add successful, the device will wake up to receive the
setting command from Z-Wave
TM
controller about 20 seconds.
Remove
1.
Have Z-Wave
TM
controller entered exclusion mode.
2.
Pressing tamper key three times within 1.5 seconds to enter
the exclusion mode.
Node ID has been excluded.
Reset
Notice: Use this procedure only in the event that the primary
controller is lost or otherwise inoperable.
1.
Pressing tamper key four times within 1.5 seconds and do
not release the tamper key in the 4
th
pressed and the LED will
light ON.
2.
After 3 seconds the LED will turn OFF, after that within 2
seconds, release the tamper key. If successful, the LED will light
ON one second. Otherwise, the LED will flash once.
3.
IDs are excluded and all settings will reset to factory default.
Association
1.
Have Z-Wave
TM
controller entered association mode.
2.
Pressing tamper key three times within 1.5 seconds to enter
the association mode.
Note: The device supports 2 groups. The group 1 is for receiving
the report message, like triggered event, temperature, illumination
etc. The group 2 is for light control, the device will send the “Basic
Set” command to this group. And each group support 8 nodes
maximum.
•
Failed or success in add/remove the node ID can be viewed from Z-Wave
TM
controller.
Notice 1:
Always RESET a Z-Wave
TM
device before trying to add it to a Z-Wave
TM
network
Notice 2:
When the device into NWI mode, the sensor functionality will useless. The
NWI modes will timeout after 30 seconds. You can press the tamper key 3 times to
abort the NWI mode.
Z-Wave
TM
Notification
After the device adding to the network, it will wake-up once per day in default. When it
wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-
up 10 seconds for receive the setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours.
And the interval step is 30 minutes.
If the user wants to wake-up the device immediately, please remove the front cover,
and press the tamper key once. The device will wake-up 10 seconds.
Operation Mode
There are two modes “Test” and “Normal”.
“Test Mode” is for the user to test the sensor function at installation.
“Normal Mode” for the normal operation.
When the event is triggered, normally the LED won't indicate, unless the battery is in
the low level, the LED will flash once. But in the “Test Mode” the LED will also light ON
for one second.
When the event triggered, the device will report the messages to the nodes in the
group 1. The messages also include the battery level, the temperature and the
illumination level. The user can switch the report by setting the configuration NO.5 bit4
(illumination), bit5 (temperature), and the configuration NO.7 bit6 (battery).
When the event is triggered and the environment luminance is less than the setting of
the value of the configuration NO. 4, the device will emit the signal to turn ON the
lighting equipment, those nodes are in the group 2. And delay a while to turn OFF the
lighting equipment. The delay time is setting by the configuration NO. 9.
The PIR motion re-detected interval in the “Test Mode” is fixed to 6 seconds. In the
“Normal Mode” it is according to the setting of the configuration NO. 8.
Notice:
When the tamper key of the back side is released, the device is always in the
“Test Mode”, no matter the DIP switch setting.
Battery Installation
When the device reports low battery message, the user should replace the battery with
new one. The battery type is CR123A, 3.0V.
Please, follow below steps to open the front covers.
1.
Using a tool press the 1-1 position and release the cover.
2.
Hold the front cover and pull back
3.
Hold the front cover and pull up