IMPORTANT PRODUCT /SAFETY INFORMATION

 

Before installing and using your Cobra power inverter, please read these general precautions and 

warnings. 
Caution and Warning Statements 

Special attention must be paid to the 

CAUTION

 and 

WARNING

 statements in the manual. 

CAUTION: 

Statements specify conditions which could cause damage to the unit or other equipment. 

WARNING:

 

Statements identify conditions that could result in personal injury or loss of life. 

General Precautions 
1. 

Never install the inverter in a boat’s engine compartment where gas and battery fumes are 

present. 

2.

 

Do not operate the inverter if it has been dropped or damaged in any way. 

3.

 

Do not open the inverter; it contains no user-serviceable parts. Attempting to service unit could 

cause electrical shock. 

NOTE:

 

Internal components remain charged after all power is disconnected. 

3.

 

Do not expose the inverter to rain, snow, bilge water or spray. 

4.

 

Do not obstruct the ventilation openings. 

5.

 

Do not install the inverter in zero-clearance compartment. 

6.

 

Do not allow water or liquids in contact with the power inverter 

7.

 

Do not use appliances with damaged or wet cords.

 

CAUTION:

 

This inverter should be used in 

negative

 

ground 

applications only. 

CAUTION:

 

The inverter must only be connected to batteries with a nominal output voltage of 12 

volts. Do not connect the power inverter to a 6 Volt battery and will be damaged if connected to a  

24 Volt battery. 

WARNING:

 

Power inverters contain components that tend to produce arcs or sparks. To prevent fire 

or explosion, do not install the inverter in areas or compartments containing batteries or flammable 

materials or in locations that require ignition-protected equipment. 

WARNING:

 

To avoid fire, do not cover or obstruct the ventilation openings. 

Do not install the power 

inverter in a tight space or closed compartment where airflow may be restricted

.

 

 

Proposition 65: Warning: Wash Hands After Handling Power Cord 

The power cord on this product contains lead, a chemical known in the state of California to cause 

birth defects or other reproductive harm. 

 
 

Содержание CPI500W

Страница 1: ...1 P a g e 2020 Cobra Electronics Corporation Version A...

Страница 2: ...OTECTION 7 GETTING STARTED 8 POWER CONSUMPTION 8 MOUNTING THE INVERTER 9 POWER 500W INSTALLATION 10 CONNECTING TO THE BATTERY 11 POWER 500W 12V ACCESSORY INSTALLATION 12 CONNECTING TO THE 12V ACCESSOR...

Страница 3: ...ehold appliances and electronic products in automobiles RVs boats trucks and virtually anywhere else with a 12 Volt battery PRODUCT SERVICE AND SUPPORT For any questions about operating or installing...

Страница 4: ...4 P a g e CONTROLS AND CONNECTIONS...

Страница 5: ...SB A Fast Charge port 5V 9V 15W E Power Fault LED Indicator F USB C Fast Charge port 5V 9V 15W G Port for Cobra Remote On Off Controller with Fast Charge USB Sold Separately H 2 GFCI Protected AC Outl...

Страница 6: ...the ventilation openings 5 Do not install the inverter in zero clearance compartment 6 Do not allow water or liquids in contact with the power inverter 7 Do not use appliances with damaged or wet cord...

Страница 7: ...safely Cobra 500W Output Waveform Some very sensitive electronic equipment may not operate satisfactory on the output waveform referred to as modified sine wave which this inverter is designed It is...

Страница 8: ...om the power inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive batteries usually 25 ampere or ampere hour capacity...

Страница 9: ...k MOUNTING THE INVERTER Do not mount the power inverter under the hood of any vehicle Choose a cool dry and well ventilated area inside the vehicle as close to the battery as possible Place the power...

Страница 10: ...10 P a g e POWER 500W INSTALLATION...

Страница 11: ...e to the terminal on the vehicle battery 8 Visually inspect and make sure the red wire or its connectors are not touching any metal parts of the vehicle or the black wire connectors 9 Connect the othe...

Страница 12: ...12 P a g e POWER 500W 12V ACCESSORY INSTALLATION...

Страница 13: ...Connect the BLACK 12V Accessory Cable ring to the BLACK inverter terminal 6 Screw the thumb cap back on the BLACK inverter terminal 7 Make sure the inverter is in the OFF position O 8 Plug the 12V Ac...

Страница 14: ...rating should be sized to allow operation of all your DC powered equipment CAUTION Remove any jewelry watch ring etc Be careful not to short circuit the battery with any metallic object wrench etc CA...

Страница 15: ...osition the inverter draws no current from the battery When it s in the on position but no power is being supplied to a load the inverter draws less than 600 milliamperes from the battery This is low...

Страница 16: ...internal alarm and or flash of the red light is normal at start up OPERATING LIMITS Power Output The inverter can deliver 500 watts for about 60 minutes The inverter must cool for 15 minutes before it...

Страница 17: ...n la on openings in the inverter are not obstructed Reduce ambient temperature No output voltage Protect indicator lighted High input voltage Make sure the inverter is connected to 12V ba ery Check re...

Страница 18: ...0A 9V 1 67A Fast Charge USB C Output Port 5V 3 0A 9V 1 67A Fast Charge AC Output Socket 2 GFCI Protected AC Outputs Protection Overload Over Temperature Short Circuit Reverse Polarity Over Under Volta...

Страница 19: ...ary from state to state Exclusions This limited warranty does not apply 1 To any product damaged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations...

Страница 20: ...erior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are fre...

Отзывы: