background image

5

4

Installation
Requirements

To check your inverter’s performance before installation:

1.

Turn the inverter

off

(see page 11

for details). If the power source
is a DC power supply, switch it

off

as well.

2.

Connect cables to power input
terminals (see page 7 for details).

3.

Connect cables to power source
(see page 7 for details).

4.

Check to make sure all
connections are secure.

5.

Turn the inverter

on

. If the

power source is a DC power
supply, switch it

on

first.

6.

Plug in the test load.

The inverter should supply
power to the load. If the inverter
is not working properly, refer to
the troubleshooting guide on
page 14 or power and protection
indicators section on page 12.

Installation Requirements

The inverter must be installed in an area that meets
all of the following requirements:

A. Dry

Do not place in an area where water can drip
or splash on the inverter.

B. Cool

Ambient air temperature should be between 30°F
and 105°F (0°C and 40°C). The cooler the better.

C. Ventilate

Allow at least one inch (three cm) of clearance around
the inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.

D. Safe

Do not install the inverter in the same compartment
as a battery or in any compartment that contains
flammable liquids such as gasoline.

E. Close to Battery

Install unit as close to battery as possible (without
being in the same compartment) to minimize the
length of cable required to connect the inverter to
the battery. It is better and cheaper to run longer
AC wires than longer DC wires (cables).

CAUTION

To avoid fire, do not cover or obstruct

ventilation openings. Do not install inverter in a zero-
clearance compartment. Overheating may result.

CAUTION

The inverter must only be connected to

batteries with a nominal output voltage of 12 volts.
It will not work with a 6 volt battery, and will be
damaged if it is connected to a 16 volt battery.

WARNING

This unit contains components which

can produce arcs or sparks. To prevent fire or
explosion, do not install in compartments containing
a battery or flammable materials, or in a location
which requires ignition protected equipment.

Installation

Quick Evaluation
Before Installation

Introduction

Nothing

Comes Close to a Cobra

®

On/Off Switch to Off

Connect Terminals

Connect Power Source

On/Off Switch to On

USB Connection

Connect Test Load

Содержание CPI 880

Страница 1: ...assistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m...

Страница 2: ...Ship prepaid and insured by way of a traceable carrier such as United Parcel Service UPS or Priority Mail to avoid loss in transit to Cobra Factory Service Cobra Electronics Corporation 6500 West Cort...

Страница 3: ...nt WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fum...

Страница 4: ...nd produces a low voltage output If the label on the AC adapter or charger states that it produces a low voltage AC or DC output less than 30 volts the inverter will have no problem powering the adapt...

Страница 5: ...hat ventilation openings on the ends of the unit are not obstructed D Safe Do not install the inverter in the same compartment as a battery or in any compartment that contains flammable liquids such a...

Страница 6: ...is so it can deliver the maximum amount of energy to the load Only use the cables provided with your power inverter To connect the cables between the inverter and the battery 1 Turn the On Off Switch...

Страница 7: ...at has high power consumption loads It will not operate electric heaters air conditioners stoves and other electrical appliances that consume more than 800 watts CAUTION Loose connectors result in exc...

Страница 8: ...tion For each piece of equipment you will be operating from the inverter you must determine the battery s reserve capacity how long the battery can deliver a specific amount of current in automotive b...

Страница 9: ...ion Operating Limits Operation Operating Limits Power Output The inverter can deliver 800 watts for about 60 minutes The inverter must cool for 15 minutes before it can resume operation at 800 watts N...

Страница 10: ...ed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Problem Symptom Low output voltage No output voltage No output voltage after prolong...

Страница 11: ...This limited warranty does not apply 1 To any product damaged by accident 2 In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs 3 If the serial number...